Air-Conditioners For Building Application
OUTDOOR UNIT

PURY-P-YMF-C

INSTALLATION MANUAL

For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.

INSTALLATIONSHANDBUCH

Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.

MANUEL D’INSTALLATION

Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte.

MANUAL DE INSTALACIÓN

Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.

MANUALE DI INSTALLAZIONE

Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d’aria.

INSTALLATIEHANDLEIDING

Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.

MANUAL DE INSTALAÇÃO

Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.

E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™

°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘ ÚÈÓ ·Ú¯›ÛÂÙ ÙËÓ
ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÌÔ‡.

РУКОВОДСТВО ПО УСТАНОВКЕ

Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по
установке до выполнения установки кондиционера.

MONTAJ ELK‹TABI

Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› monte etmeden önce bu elkitab›n› dikkatle okuyunuz.

GB

D

F

I

NL

E

P

GR

RU

TR

Summary of Contents for CITY MULTI PURY-P400YMF-C

Page 1: ...leggere attentamente questo manuale di installazione prima di installare il condizionatore d aria INSTALLATIEHANDLEIDING Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert MANUAL DE INSTALAÇÃO Para segurança e utilização correctas leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado E XE...

Page 2: ...10 56 56 A D 150 Ø62 Ø27 230 111 B A Fig 6 1 2 A Top view B Side view C When there is little space up to an obstruction A Front B No restrictions on wall height left and right C Air outlet guide Procured at the site A Knock out hole B Bottom piping C Front piping A M10 anchor bolt procured at the site B Corner is not seated A Bottom piping through hole B bolt hole C bolt hole for old models D Bott...

Page 3: ...sory D Connecting pipe Accessory E Open Operate slowly F Cap copper packing G Service port H ø25 4 I ø34 93 J Field piping K Close packed packing L Hollow packing A System analyzer B Lo Knob C Hi Knob D Ball valve E Low press pipe F High press pipe G Service port H Three way joint I Valve J Valve K Cylinder L Scale M Vacuum pump A Nitrogen gas B To indoor unit C System analyzer D Lo Knob E Hi Knob...

Page 4: ...IC 51 M1M2S TB5 RC 01 IC M1M2S TB5 03 IC M1M2S TB5 02 IC M1M2S TB5 04 IC M1M2S TB5 05 IC M1M2S TB5 07 IC M1M2S TB5 06 L 2 L1 101 RC 105 RC 104 RC 155 OC M1M2 M1M2S TB7 TB3 53 OC r3 BC M1M2S 52 BS M1M2S 55 BC M1M2S 54 M1M2S Power Supply Unit M1M2S MJ103 L3 L 6 L 7 L4 L 5 r 2 r 4 r 1 A B A B A B A B A Steel wire B Piping C Asphaltic oily mastic or asphalt D Heat insulation material A E Outer coverin...

Page 5: ...Fig 9 4 1 E E D A E E A B C C 3 N 380 450 V 220 240 V L N PE L1 L2 L3 N PE A Switch Breakers for Wiring and Current Leakage B Outdoor Unit C BC Controller master C BC Controller slave D Pull Box E Indoor Unit ...

Page 6: ... the refrigerant leak and cause the safety limit to be exceeded hazards due to lack of oxygen in the room could result When moving and reinstalling the air conditioner consult the dealer or an authorized technician If the air conditioner is installed improperly water leakage electric shock or fire may result After completing installation work make sure that refrigerant gas is not leaking If the re...

Page 7: ...t may cause the refrigerator oil to deteriorate Use a vacuum pump with a reverse flow check valve The vacuum pump oil may flow back into the refrigerant cycle and cause the refrigerator oil to deteriorate Do not use the following tools that are used with conventional refriger ants Gauge manifold charge hose gas leak detector reverse flow check valve refrigerant charge base refrigerant recovery equ...

Page 8: ...ving particles oils moisture or any other contaminant For R407C models 2 Commercially available piping often contains dust and other materials Always blow it clean with a dry inert gas 3 Use care to prevent dust water or other contaminants from entering the piping during installation 4 Reduce the number of bending portions as much as possible and make bend ing radius as big as possible 5 Always ob...

Page 9: ...ge hose gas leak detector check valve refriger ant charge base vacuum gauge refrigerant recovery equipment Mixing of conventional refrigerant and refrigerator oil may cause the refrig erator oil to deteriorate Mixing of water will cause the refrigerator oil to deteriorate R407C refrigerant does not contain any chlorine Therefore gas leak detec tors for conventional refrigerants will not react to i...

Page 10: ...m 250 kg cm or more G Service port Use this port to evacuate the refrigerant piping and add an additional charge at the site Open and close the port using a double ended wrench Always reinstall the cap after operation is completed Service port cap tightening torque 14 N m 140 kg cm or more H ø25 4 I ø34 93 J Field piping Braze to the connecting pipe When brazing use unoxidized brazing K Close pack...

Page 11: ...ng for control hereinafter referred to as transmission line shall be 5 cm or more apart from power source wiring so that it is not influenced by electric noise from power source wiring Do not insert transmission line and power source wire in the same conduit 3 Be sure to provide designated grounding work to outdoor unit 4 Give some allowance to wiring for electrical part box of indoor and outdoor ...

Page 12: ...its and the total number of remote controllers is displayed within the parenthesis 1 If even one unit that is higher than 200 exists in the cooling system the maximum capacity will be 200 or higher Branch Setting Set the indoor unit branch No switch to the branch No of the BC controller connecting the piping and that indoor unit When using two or more branches set the lowest branch No The indoor u...

Page 13: ... to the same branch of the BC controller the heating cooling operation cannot be performed while another indoor unit is performing a cooling heating operation Because of the control operation of auto vane it may change over to horizontal blow automatically from the downward blow in cooling in case the downward blow operation has been continued for 1 hour At defrosting in heating hot adjust ing and...

Page 14: ...e contact address telephone number on this manual before handing it to the customer The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commer cial and light industrial environment ...

Page 15: ...mber PURY P500YMF C PURY P400 500YMF C_Service_Manual_ MDOC PURY P400 500YMF C_Declaration_of_Conformity PURY P400 500YMF C_Installation_Manual_ WT03692X01 PURY P400 500YMF C_Parts_Catalog_ BWE02030 PURY YMF C_DataBook_2002 ...