3.6.17 UNIT STATUS = STA
There is no SET command.
The QUERY command requires no parameters.
Remote Command Sequence: ?STA
Unit Response: ?STAFffffffffffffTtttLlIiMmRrPp?abcdefghi
F: Frequency indicator
ffffffffffff: Twelve-digit ASCII numeric characters indicating the frequency in Hz.
T: Attenuation indicator
ttt: Three-digit ASCII numeric characters indicating the attenuation in tenths of a dB.
L: Local / Remote mode indicator
l: "0" or "1" ASCII numeric character
0 = Local control
1 = Remote control
I: IF indicator
i: "0" No IF selection available
M: Mute status indicator
m: "0" or "1" ASCII numeric character
0 = not mute
1 = mute.
R: Frequency Reference Source indicator
r: "0" or "1" ASCII numeric character
0 = internal
1 = external.
P: Polarization indicator
p: "0" No Polarization selection available
?: Component Fault Status indicator
a-i: "0" or "1" ASCII numeric character
0 = No fault
1 = Fault
a-i indicates the status of the component faults described in the ALR command.