LED state
Description
Power LED blinking green 3 cycles per second,
50% duty.
Waiting for DHCP (IPv4 or IPv6) answer or IPv6
router advertisement or PPPoE connection. No Ip
Address configured.
Ready LED OFF, all other LEDs cycling from
right to left, left to right.
The unit tries to download and install a firmware
given by the Network Rescue server.
RESET/DEFAULT Button
The
Reset/Default
button is a switch that can be used to perform a partial or factory reset while the unit
is running.
In other words, the
Reset/Default
button can be used to:
•
Cancel an action that was started.
•
Revert to known factory settings if the Mitel GX Gateway refuses to work properly for any reason
or the connection to the network is lost.
•
Reconfigure a unit.
The
Reset/Default
button will generate different actions depending on the amount of time the button is
held.
IMPORTANT
:
It is the LED pattern that will indicate the action that is being applied to the unit. The
action will occur more or less rapidly depending on the platform.
LED Pattern
Action
Comment
Power1 blinking, all other LEDs
OFF
Restarts the Mitel GX Gateway. No changes are made to the
Mitel GX Gateway settings.
All LEDs blinking, 1cycle per
second, 50% duty
Initiates a Partial Reset of the
Mitel GX Gateway.
Note:
The partial reset is
optional as it can be disabled
with the CLI
Hardware.ResetButtonManagement
parameter. For more details, refer
to the
published on the
Media5 documentation portal at
https://
documentation.media5corp.com/
Restarts the unit in a known and
static state while keeping most
of the configuration unchanged.
All LEDs steady ON
Initiates a Factory Reset of the
Mitel GX Gateway.
Reverts the unit back to its
default factory settings.