GUIDE TO INSTALLATION AND OPERATION
38
| Kaleido-Solo
1st Loudness/2nd Loudness - Target
This parameter will change the target value in loudness chart. Altering this value will uncheck the EBU or A-85 Mode.
1st Loudness/2nd Loudness - Short-Term Time Window
Changing this parameter affects the short term calculation. Altering this value will uncheck the EBU or A-85 Mode.
The choices are:
1 sec
..
15 sec
1st Loudness/2nd Loudness - Relative Gating
Changing this parameter affects the relative gating calculation. Altering this value will uncheck the EBU or A-85 Mode.
The choices are:
-8 dB
-10 dB
1st Loudness/2nd Loudness - Alarm | Upper Tolerance
This parameter sets the maximum allowable value for the integrated (I) measurement without triggering an alarm.
e.g.: Upper Tolerance set to -20. If the integrated measurement is -19, then an alarm is triggered. If the integrated
measurement is -20, then no alarm is triggered.
1st Loudness/2nd Loudness - Alarm | Lower Tolerance
This parameter sets the minimum allowable value for the integrated (I) measurement without triggering an alarm.
e.g.: Lower Tolerance set to -25. If the integrated measurement is -26, then an alarm is triggered. If the integrated
measurement is -25, then no alarm is triggered.
1st Loudness/2nd Loudness - Alarm TPmax Tolerance
This parameter sets the maximum allowable value for the true peak max measurement without triggering an alarm.
e.g.: TPmax set to -5. If the true peak max measurement is -4, then an alarm is triggered. If the true peak max
measurement is -5, then no alarm is triggered.
Note that if the TPmax
tolerance is set to 0, no alarm will ever be triggered.
Alarm
An alarm is:
-
A red border around the loudness chart.
-
A red box around the measurement in error (full screen chart only see section 5.5.2).
-
An optional GPI Output activated (see section 5.9).
-
Logged by iControl / iControl solo (see section 5.4.7).