GUIDE TO INSTALLATION AND OPERATION
Kaleido-Solo |
37
5.4.6 Audio - Loudness Advanced
1st Loudness/2nd Loudness - Meter Mode
EBU Mode G8
The loudness chart will follow the EBU R128-2010 recommendation with the relative gating at
-8dB.
For legacy support.
EBU Mode G10
The loudness chart will follow the EBU R128-2011 recommendation with the relative gating at
-10dB.
A85 ITU BS.1770-1
The loudness chart will follow the ATSC A/85 recommendation.
For legacy support.
A85 ITU BS.1770-2
The loudness chart will follow the ATSC A/85 recommendation.
ARIB TR-B32
The loudness chart will follow the ARIB TR-B32 recommendation.
Note that if there is a star in front of a parameter (e.g.: * Relative Gating) it means that the parameter has
been changed from its default value. These changes could affect the measurements.
Note that if there are stars in front of the mode name in the loudness chart (e.g.: * EBU R128-2011) it
means that the measurement respects the EBU algorithm except parameters that were manually
changed. These changes could affect the measurements.