ReferenceError! Bookmark not defined. Offset
This menu displays the Reference offset in lines and µ-seconds where the
offset range is
±
½ field.
PAL
=
±
312.5lines @ .018µS increments
NTSC
=
±
262.5lines @ .018µS increments
1920 x 1080i/59.94 Hz
=
±
562.5lines @ .013µS increments
1920 x 1080i/50 Hz
=
±
562.5lines @ .013µS increments
1280 x 720/59.94 Hz
=
±
375lines @ .013µS increments
1280 x 720/50 Hz
=
±
375lines @ .013µS increments
To adjust the offset use the arrow control keys
§
¨
.
Adjusting reference timing
Warning
:
Reference timing should always be adjusted off-air since it can result in loss
of picture in downstream equipment. Errors may occur in the SDI stream
whilst the adjustment is taking place.
Serial Comms Setup
This sets the baud rate and protocol for the RS232 communication port on the
rear panel.
IP Address
This option displays the units IP Address number and enables the user to
modify it.
The IP Address will be shown on the VFD display with a plus (+) and minus
(-) symbol at either end indicating that the value can be adjusted between (0
and 255).
The number is in four blocks separated by full stops i.e.
10.96.98.240
Summary of Contents for Imagestore Intuition+
Page 10: ...Preface Imagestore Intuition User Manual Page 10 Miranda Technologies Ltd Index Manual index ...
Page 16: ...Table of Contents Imagestore Intuition User Manual Page 16 Miranda Technologies Ltd ...
Page 44: ...Front Panel Operation Imagestore Intuition User Manual Page 44 Miranda Technologies Ltd ...
Page 60: ...Index Imagestore Intuition User Manual Page 60 Miranda Technologies Ltd ...