18
5
4
7
3
8
2
9
1
Low Pressure
High
Medium
Low
Stop
Temperature
Service
Flow
100
Minimum
10 Minimum
Rising
Back Inlet
Supply
Falling
Back Inlet
Supply
Falling
Supply
Rising
Supply
Front of
Mira
Advance
ATL
?
"
#
Tap Connector
Adaptor
(supplied)
Fibre Washer
1.7. Determine whether the cold water
and cable supplies will be top (falling),
bottom (rising), or back inlet to the
Mira Advance ATL.
1.8. Swivel the inlet connector assembly
to suit (not directly back into the
wall). Avoid trapping the green earth
bonding wire.
1.9. Remove as appropriate, the thinned
sections in the Mira Advance ATL
case, to allow the pipe and cable to
enter the product.
1.10. Install the mains-fed cold water
supply pipe
The Mira Advance ATL can be
connected to either a compression
fitting (supplied) or a tap connector
(not supplied).
If upgrading from other Mira
Advances that use a tap connector,
then the tap connector adapter can
be used in place of the fibre washer.
This allows the tap connector to be
used in conjunction with the
compression fitting of the product
(see diagram).
For back inlet supplies, the cold
water pipe must emerge from the
walls surface 'square' to prevent
straining the inlet connector clamp
bracket. See diagram for options.
1.6. When deciding the position of the
Mira Advance ATL on the wall:
Allow 100mm minimum clearance
to the right hand side of the case, to
provide unrestricted access to the
inlet connector, for installation and
future maintenance.
Allow 10mm minimum clearance from
the top of the case to allow the cover
to be removed.