background image

1  |  minnkotamotors.com

©2022 Johnson Outdoors Marine Electronics, Inc.

C

• 

Wire Stripper

• 

Pencil or marking tool

• 

Wire Cutter

• 

Ruler

• 

Heat Gun

• 

Drill

• 

1-¾" Hole Saw

• 

1/8" Drill Bit

• 

Phillips Screw Driver

Before installing your Trolling Motor Plug and Receptacle, consider  
the following:

1.  The mounting surface needs to have a flat area no less  

than 3-¼” wide x 2-½ inches high. Use the Face Plate (Item  
#2) to check for clearance at the desired mounting location.

Item / 

Assembly

Part #

Description

Qty. 

A

2996707

PLUG ASSEMBLY

1

B

2996708

RECEPTACLE

1

C

2990214

COVER-DUST ASSEMBLY

1

2

2376458

PLATE-FACE

1

4

2375425

COVER-SPLICE  

1

Includes 6-14

2994953

BAG ASM, PLUG SIDE,TM PLUG

1

6

2095400

SHRINK TUBE,16MM, 2”, 4:1

2

8

2375440

SPLICER, 6-10 AWG, TIN PLTD

2

10

2372951

FERRULE, 8 AWG, .47”, TIN PLTD

4

12

2372952

FERRULE,10 AWG, .47”, TIN PLTD

2

14

2376740

KEY-3/32” HEX L, STEEL

1

Includes 16-34

2994954

BAG ASM, RECPT SIDE,TM PLUG

1

16

2375402

SHRINK TUBE-24MM ID X 3.5”

2

18

2375442

SPLICER, 2/0-14 AWG

2

20

2372953

FERRULE,1 AWG,.71”,TIN PLT

2

22

2372954

FERRULE,2 AWG,.71”,TIN PLT

2

24

2372955

FERRULE,4 AWG,.71”,TIN PLT

2

26

2372950

FERRULE, 6 AWG, .47”, TIN PLTD

2

28

2372951

FERRULE, 8 AWG, .47”, TIN PLTD

4

30

2372952

FERRULE,10 AWG, .47”, TIN PLTD

2

32

3393400

SCREW-#8-18X1-1/4 PPHSMS SS

4

34

2376741

KEY-3/16” HEX L, STEEL

1

2377182

INSTR.SHEET,TROLLNG MTR PLG

1

36

2374651

O-RING (INCLUDED IN ASSEMBLY B)

1

Includes A & D

2776707

PLUG ASM, TROLLING MTR PLUG KIT

1

Includes B & E

2776708

RECEPTACLE ASM, TRL MTR PLUG

1

TOOLS AND RESOURCES REQUIRED

MOUNTING CONSIDERATIONS

MKR-28 

TROLLING MOTOR PLUG AND RECEPTACLE 

1865120

 

This part is included in an assembly and cannot be ordered individually. 

 Not shown on Parts Diagram.  

WARNING

Do not tin any wires with this installation. Tinned wires could 
cause the connection to loosen over time, creating an improper 
connection. Improper connections could cause ae electrical 
short or extreme fire danger. Follow the installation instructions 
provided to avoid product failure and injury.

WARNING

Make sure the power source is disconnected or, if controlled by 
a switch, turned OFF before beginning installation of the Plug 
Receptacle. Failure to remove power from the Boat Wires could 
cause electric shock.  

NOTICE: 

If uncomfortable making this installation, we 

recommend having the Motor Plug and Receptacle 
installed by a qualified marine installer.

A

F

4

36

B

D

8

12

10

6

14

20

22

24

26

28

30

E

34

18

32

16

G

2

Summary of Contents for 1865120

Page 1: ...ULE 6 AWG 47 TIN PLTD 2 28 2372951 FERRULE 8 AWG 47 TIN PLTD 4 30 2372952 FERRULE 10 AWG 47 TIN PLTD 2 32 3393400 SCREW 8 18X1 1 4 PPHSMS SS 4 34 2376741 KEY 3 16 HEX L STEEL 1 2377182 INSTR SHEET TRO...

Page 2: ...any sort of electrical connector that should be removed NOTICE For ease of installation it is recommended to stagger the ends of the wires by 1 Make the Negative Boat Wire the shorter wire of the two...

Page 3: ...re red Wire red Negative Negative Boat Wire Boat Wire Negative Negative Wire black Wire black Negative Negative Wire black Wire black Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle NO...

Page 4: ...nk Tubes when heated Push the wires and the Plug Receptacle into the drilled hole until the Plug Receptacle sits against the mounting surface 5k Shrink Shrink Tubes Tubes Plug Receptacle Plug Receptac...

Page 5: ...k for clearance of other items on the mounting surface and if the cord will interfere with the operation of anything in the area r Once in an acceptable location take a pen or marking tool and mark th...

Page 6: ...Lead Positive Power Lead Positive Power Lead Negative Power Lead Negative Power Lead Negative Power Lead Negative Power Lead Negative Power Lead Negative Power Lead Negative Power Lead Negative Power...

Page 7: ...the red Positive Power Lead on the Plug Assembly and align it with the Positive Power Lead on the Trolling Motor Wires Insert it into the Splicer at the end of the Positive Lead Wire from the Plug Ass...

Page 8: ...2372951 FERRULE 8 AWG 47 TIN PLTD 4 30 2372952 FERRULE 10 AWG 47 TIN PLTD 2 32 3393400 SCREW 8 18X1 1 4 PPHSMS SS 4 34 2376741 KEY 3 16 HEX L STEEL 1 2377182 INSTR SHEET TROLLNG MTR PLG 1 36 2374651...

Page 9: ...doit tre retir AVIS Pour faciliter l installation nous vous recommandons de d caler les extr mit s des fils de 1 po 31 75 mm Faites en sorte que le fil de bateau n gatif soit le plus court des deux fi...

Page 10: ...u Fil de bateau positif positif Fil positif Fil positif rouge rouge Fil de bateau Fil de bateau n gatif n gatif Fil n gatif noir Fil n gatif noir Fil n gatif noir Fil n gatif noir Prise de fiche Prise...

Page 11: ...cissables lorsqu elles sont chauff es Poussez les fils et la prise de fiche dans le trou perc de mani re ce que la prise de fiche repose contre la surface de montage 5k Gaines Gaines thermor tr cissa...

Page 12: ...autres articles sur la surface de montage et v rifiez si le cordon risque de nuire au fonctionnement de tout l ment dans la zone r Lorsque vous tes dans un emplacement acceptable prenez un stylo ou un...

Page 13: ...ble d alimentation n gatif n gatif C ble d alimentation n gatif C ble d alimentation n gatif C ble d alimentation n gatif C ble d alimentation n gatif C ble d alimentation n gatif C ble d alimentation...

Page 14: ...d alimentation positif rouge dessus puis alignez le sur le c ble d alimentation positif des fils du moteur de p che la tra ne Ins rez le dans l pisseur l extr mit du fil conducteur positif de l ensemb...

Reviews: