background image

3

4

2

Equipment Features

Model

MT01CP

AC100〜240V 50/60Hz

Maximum 8.7A(for AC100V)Maximum 4.4A(for AC200V)

0℃〜40℃

30L / min(0.25〜0.3MPa)

500〜60,000min 

‑1      

*500min 

‑1

 is the alignment setting.

5,000〜60,000min 

‑1

4.1Kg

W100xD194xH230

3

Specifications and Dimensions

3‑1 Specifications

3‑3 Torque Output Characteristics(Motor Spindle)

3‑5 Accessories

‑10〜60℃ 

*Do not use in an envirment with heavy condensation

.

      

 10〜85%  

*Do not use in an envirment with heavy condensation

.

When  operating  the  device  continuously,check  the  aspect  of  loads  in  the 
LEVEL meter.Refer to Chart‑2 for the tolerance level per speed of rotation.

◆CA20 / CA21 / CA22 ※

◆MRZ2…

4pieces

◆MRZ3…

4pieces

◆MTB1…

2pieces

◆MTB2…

2pieces

◆AH6‑40

φ6.0×4m

※Either one of them
※It is attached to CA20 
  a 3p→2p adapter.

3‑4 The confirmation of a level meter used consecutively

3‑2 Dimensions of External Appearance

M4x0.7

100

50

214

194

148

66

17

4.6

25

230

250

250

271

M4x0.7

100

194

216
238

66

17

240

230

10

15

50

4.6

80

Maximum Output
A stable, high torque is achieved with a high‑power 370W of sufficient output by loading 
of a high‑power electric source.

Worldwide Power Supply
It is equipped with an AC100〜240V‑compliant worldwide power supply. Thus, gone are trou‑
blesome changes in power‑supply settings and failures by voltage difference.

Various Security
It is equipped with a safety security function to constantly monitor the load condition 
of the main axis, overcurrent to motor, heat generated by power‑supply and air pressure.

Maximum Speed of Rotation 60,000min ‑1
Motor  spindles  of  the  01  series  are  equipped  with  a  high‑performance,  brushless  motor 
with ceramic angular bearings, allowing a maximum speed of 60,000min‑1 rpm. The adopted 
forced air‑cooling system (outer burner cooling) allows for high durability. 

Air‑Cooling System
The adopted forced air‑cooling system requires only a small amount of air(30L/min),
preventing heat generated by motor over prolonged use.

Electric Power

Input Current

Service Temperature Range

Air Consumption

Range of RPM setting

An effective use range

Weight

Dimension

Storage temperature

Storage humidity

・Fig.‑1  Floor mounting type

・Fig.‑2  Back face mounting type

1

2

3

4

5

6

7

8

9

0

10

20

30

40

50

60

50

100

150

200

250

300

350

400

 Performance characteristic graph

Torque

cN・m

Output

(W)

Output

Torque

(Unit Continuum Region)

Torque (Maximum)

Speed of Rotation ×1000(min

‑1

The Number of

Revolution Displayed

10
20
30
40
50
60

The Number of 

LEVEL Lightings

6
6
5
5
4
4

Color of 

the Light

Yellow
Yellow
Green
Green
Green
Green

・Chart‑2

AC cable

air‑hoses

Mounting screw

blackest

Rubber feet 

・Chart‑1

Summary of Contents for SFIDA 01 Series

Page 1: ...AN Osaka Br 4 4 Itachibori 2 chome Nishi ku Osaka 550 0012 Nagoya Br 4 Kanayamacho 1 chome Atsuta ku Nagoya 456 0002 Phone 03 3633 7181 Fax 03 3633 7186 Phone 06 6531 5300 Fax 06 6531 5417 Phone 052 671 3077 Fax 052 671 3177 Specifications and configurations are subject to change without notice http www minitor co jp 01 Series ...

Page 2: ...n for repair after confirming that all smoking has stopped If the machine is damaged and used without proper repair fire and electric shock could result Do not attempt to modify or disassemble the machine since this can cause serious loss in performance and safety otherwise fire and electric shock could result Be sure to only use the input voltage specified in this device since fire and electric s...

Page 3: ...gone are trou blesome changes in power supply settings and failures by voltage difference Various Security It is equipped with a safety security function to constantly monitor the load condition of the main axis overcurrent to motor heat generated by power supply and air pressure Maximum Speed of Rotation 60 000min 1 Motor spindles of the 01 series are equipped with a high performance brushless mo...

Page 4: ... the speed of rotation will continue to decrease to a minimum setting of 1 000min 1 When the switch is pressed in the indication of 1 000min 1 at the time of a motor stop it will be set at 500min 1 for alignment Note Effective working range is 5 000min 1 or more Indicator This indicates the speed setting or the speed of rotation per minute rpm and also indicates when malfunctions occur by blinking...

Page 5: ...otation direction lights up 4 Press the UP or DOWN switch so that the intended speed of rotation is displayed on the indicator 5 Press the START STOP switch to start or stop the motor 5 3 Panel Remote Operation Mode 1 Turn on the MAIN switch P E is displayed once in the Indicator Make sure that operation PANEL and both REMOTE lamps of are lit 2 Supply air to the motor Refer to the details of 5 2 P...

Page 6: ...m that F 0 is being indicated Then the display of the F 0 shall flash after having released the MODE switch 5 When pushing the switch the indication shall change e g F 0 F 1 F 2 F 3 F 8 and F 0 in turn and when pushing the switch it shall change e g F 0 F 8 F 7 F 1 and F 0 in turn while the display is flashing 23 23 21 6 The set up content of the function number will be displayed by pushing the 21...

Page 7: ...r type fixation Fig 11 and the back mounting Fig 12 Install accessory two brackets in the bottom aspect hole of this device Brackets for the Floor type fixation Fig 11 Floor type fixation Install accessory two brackets in the hole of up and down each face of this device back direction Brackets for the Back mounting Fig 12 Back mounting Caution Install this device in an environment free from powder...

Page 8: ...or The LEVEL indicator displays ones place digit of the error number and consists of nine 9 lamps The first lamp Indicates 1 of ones place digit of error number the second lamp indi cates 2 and the third lamp indicates 3 Refer to the details of 9 3 Error Numbers and Their Contents 9 2 When Malfunctions Are Detected In powered on when malfunctions is detected from storage data after the previous se...

Page 9: ...umber of rotations The revolution number hsa been set too high on the Selector Pack Current value at the time of motor in operation is low Over current protection to the motor was activated Protection functions of the motor power supply were activated Transistor for the motor brake overheated The speed of rotation does not reach number of revolutions set The speed of rotation is low at 3000 5000 m...

Page 10: ... to Control pack from the controller Once data has been sent data corresponding to the respective commands will be sent from Control Pack Data transmission request command is the following two Data Transmission Timing When transmitting data transmission request command from the controller be sure to transmit three data e g 44 41 0D continuously When data interval is set to 255ms or more the proper...

Page 11: ...sum calculation method From data No 1 to the 17th 2A Error number10 0 Upper 4 bits Lower 4 bits Add 30 respectively Lower 8 bits Checksum H Checksum L Relation between a number and ASCII code Calculation example Lower 8 bits of total to the transmitting data 1011 0101 Checksum H 1011 30 0B 30 3B Checksum L 0101 30 05 30 35 Number ASSCII code 0 30 1 31 2 32 3 33 4 34 5 35 6 36 7 37 8 38 9 39 Transm...

Page 12: ......

Reviews: