Equipment Features
Model
MT01CP
AC100〜240V 50/60Hz
Maximum 8.7A(for AC100V)Maximum 4.4A(for AC200V)
0℃〜40℃
30L / min(0.25〜0.3MPa)
500〜60,000min
‑1
*500min
‑1
is the alignment setting.
5,000〜60,000min
‑1
4.1Kg
W100xD194xH230
3
Specifications and Dimensions
3‑1 Specifications
3‑3 Torque Output Characteristics(Motor Spindle)
3‑5 Accessories
‑10〜60℃
*Do not use in an envirment with heavy condensation
.
10〜85%
*Do not use in an envirment with heavy condensation
.
When operating the device continuously,check the aspect of loads in the
LEVEL meter.Refer to Chart‑2 for the tolerance level per speed of rotation.
◆CA20 / CA21 / CA22 ※
◆MRZ2…
4pieces
◆MRZ3…
4pieces
◆MTB1…
2pieces
◆MTB2…
2pieces
◆AH6‑40
φ6.0×4m
※Either one of them
※It is attached to CA20
a 3p→2p adapter.
3‑4 The confirmation of a level meter used consecutively
3‑2 Dimensions of External Appearance
M4x0.7
100
50
214
194
148
66
17
4.6
25
230
250
250
271
M4x0.7
100
194
216
238
66
17
240
230
10
15
50
4.6
80
+
−
+
−
●
Maximum Output
A stable, high torque is achieved with a high‑power 370W of sufficient output by loading
of a high‑power electric source.
●
Worldwide Power Supply
It is equipped with an AC100〜240V‑compliant worldwide power supply. Thus, gone are trou‑
blesome changes in power‑supply settings and failures by voltage difference.
●
Various Security
It is equipped with a safety security function to constantly monitor the load condition
of the main axis, overcurrent to motor, heat generated by power‑supply and air pressure.
●
Maximum Speed of Rotation 60,000min ‑1
Motor spindles of the 01 series are equipped with a high‑performance, brushless motor
with ceramic angular bearings, allowing a maximum speed of 60,000min‑1 rpm. The adopted
forced air‑cooling system (outer burner cooling) allows for high durability.
●
Air‑Cooling System
The adopted forced air‑cooling system requires only a small amount of air(30L/min),
preventing heat generated by motor over prolonged use.
Electric Power
Input Current
Service Temperature Range
Air Consumption
Range of RPM setting
An effective use range
Weight
Dimension
Storage temperature
Storage humidity
・Fig.‑1 Floor mounting type
・Fig.‑2 Back face mounting type
1
2
3
4
5
6
7
8
9
0
10
20
30
40
50
60
50
100
150
200
250
300
350
400
Performance characteristic graph
Torque
(
cN・m
)
Output
(W)
Output
Torque
(Unit Continuum Region)
Torque (Maximum)
Speed of Rotation ×1000(min
‑1
)
The Number of
Revolution Displayed
10
20
30
40
50
60
The Number of
LEVEL Lightings
6
6
5
5
4
4
Color of
the Light
Yellow
Yellow
Green
Green
Green
Green
・Chart‑2
AC cable
air‑hoses
Mounting screw
blackest