![Minebea OPT-563B Quick Instruction Manual Download Page 26](http://html.mh-extra.com/html/minebea/opt-563b/opt-563b_quick-instruction-manual_1801129026.webp)
24
Function No.
Item
Setting
value
Details
F-41
PROFIBUS
Station No.
000~125
●
000
F-42
CANopen
Node ID
001~127
●
001
F-43
CANopen
Baud rate
0 10
kbps
1 20
kbps
2 50
kbps
3 100
kbps
4 125
kbps
5 250
kbps
6 500
kbps
7 800
kbps
●
8 1
Mbps
F-45
CANopen
PDO output frequency
0~100
0: Off
Unit: 1 ms
●
100
F-50
Maintenance 1
00000
0~99 999 (Do not use)
F-51
Maintenance 2
00000
0~99 999 (Do not use)
F-55 Calibration
prohibited
0000
0: Calibration permitted
1: Calibration prohibited
10
0
digit: Calibration data 1
10
1
digit: Calibration data 2
10
2
digit: Calibration data 3
10
3
digit: Calibration data 4
F-56 Symmetry
correction
clear
0
Clear data corrected using symmetry
correction function.
F-57
Clearing counter-clockwise
linearization correction
0
Clear data corrected using linearization
correction function. (Counter-clockwise
direction)
F-58
Clearing clockwise linearization
correction
0
Clear data corrected using linearization
correction function. (Clockwise direction)
F-59
Calibration data selection
●
0
Calibration data 1
1
Calibration data 2
2
Calibration data 3
3
Calibration data 4
F-60
Calibration 1 Increment
1
Datum value (initial value)
F-61
Calibration 1 Maximum display
value
10000
Datum value (initial value)
F-62
Calibration 1 Actual torque
value
10000
Datum value (initial value)
F-63
Calibration 1 ZERO A/D
0x1FFFF
Datum value (initial value)
F-64
Calibration 1 +SPAN A/D
0x3AAAA
Datum value (initial value)
F-65
Calibration 1 -SPAN A/D
0x5555
Datum value (initial value)
F-66
Calibration 1 ZERO frequency
conversion value
10000
Datum value (initial value)
F-67
Calibration 1 +SPAN frequency
conversion value
15000
Datum value (initial value)
F-68
Calibration 1 -SPAN frequency
conversion value
5000
Datum value (initial value)