107
8-1-6 Get Image
Original Image Ship
Format
<SYN>M<CR>
%OISHP
.
0x16 0x4D 0x0D 0x25 0x4F 0x49 0x53 0x48 0x50 0x2E
An image is taken whenever the scan operation is done. The last image is always stored in memory.
The original image can be “shipped” by using the
%OISHP
command.
Down-sampled Image Ship
Format
<SYN>M<CR>
%DISHP
.
0x16 0x4D 0x0D 0x25 0x44 0x49 0x53 0x48 0x50 0x2E
An image is taken whenever the scan operation is done. The last image is always stored in memory.
The down-sampled image can be “shipped” by using the
%DISHP
command.
8-1-7 Responses
The scanner responds to a serial command with one of three responses:
<ACK>
(0x06)
A valid command which has been processed.
<ENQ>
(0x05)
An invalid index command.
<NAK>
(0x15)
A command with a valid parameter index and an invalid value.