9
IMPORTANT:
A non-metallic screwdriver should be used when
adjusting the trim pots to avoid any possibility of the screwdriver’s
blad contacting live circuitry and shorting the circuitry or allowing
contact with any dangerous or fatal voltages.
Dangerous voltages exist on the printed circuit
board.
Contact with components and/or printed
circuitry could cause serious injury or fatality. Please
refer to the Safety Warnings on page i.
Warning
Maximum Speed and Regulation (IR COMP) Adjustment
Two potentiometers, located on the control PC board, are provided
for adjustment of the maximum motor speed and regulation of the
motor’s speed.
Calibration