8
Installation
3. Connect the power line to its appropriate wires. The hot leg of
the power line should be fused with a fast blow 0.5 amp fuse to
protect the control. The motor may be started and stopped with
the power line at any speed setting on the speed adjust pot. The
motor coasts to a stop when the power line is disconnected. If
dynamic braking is desired, see
Dynamic Braking on page 29.
Minarik strongly recommends the installation of an emergency
stop switch as shown in Figure 2 (page 5). The switch must be
rated at a minimum of 250 VAC and 150% of the maximum
motor armature rating.
Alternative Wiring
By utilizing additional components the SL10U may be operated by
external signal control, have multiple preset speeds, dynamic
braking, limit switch operation, etc.
Please refer to
Application
Notes (page 14) for these and other modes of operation.