Specifications
Max.
Armature
HP Range
HP Range
Current
with 115 VAC
with 230 VAC
Model
(Amps DC)
Applied
Applied
RG501A
10.0
1/4–1
1/2–2
RG511A
3.0
1/20–1/8 1/10–1/4
AC Line Voltage
115/230 VAC, ±10%, 50/60 Hz, single phase
Armature Voltage (115 VAC Input)
0–90 VDC
Armature Voltage (230 VAC Input)
0–180 VDC
Form Factor
1.37 at base speed
Field Voltage (115 VAC Input)
50 VDC (F1 to L1); 100 VDC (F1 to F2)
Field Voltage (230 VAC Input)
100 VDC (F1 to L1); 200 VDC (F1 to F2)
Maximum Field Current
1 ADC
Acceleration Time Range (with no load)
0.5–15 seconds
Deceleration Time Range (with no load)
0.5–15 seconds
Analog Input Voltage Range (isolated; RB1 to S2)
–10 to +10 VDC
Input Impedance (RB1 to S2)
32K ohms
Load Regulation
with Armature Feedback
1% of base speed or better
with Tachogenerator Feedback
0.1% of base speed
Dwell Time
0.1 – 1 second (0.1 second increments)
Vibration
0.5G max. (0–50 Hz)
0.1G max. (>50 Hz)
Ambient Temperature Range
10°C–40°C
Weight
8.3 lb