54
CE Addendum
If the end-user is not using a CE-approved motor, a second
filter, part number CEXXRG, must be deployed on the output.
XX = rated current of the filter.
The CEXXRG is a Real-Pole Balanced-Pi 3-pole filter. If the
exact filter is not available, the specifications are as follows:
L & L1 = 2 x (0.8) milliHenries.
C & C1 = 2 x (0.1) microFarads @ 400W VDC.
Rin = 0.1 ohm; Rout = 1.2 ohm.
Table 5. Minarik Filters
Nameplate Current of
Motor Wired to the Drive
Minarik Filter Part Number
0 to 4 amps
CE04RG
4.1 to 13 amps
CE20RG
The filters in Table 5 must be wired to the DC output of the
drive, as close to the drive as possible. The ground connection
from the filter must be wired to solid earth ground (resistance
less than 500 ohms); not machine ground. This is very
important!
The end user must use the filtration listed in Exhibit A to comply
with CE. The OEM may choose to provide alternative filtering
that encompasses the Minarik drive and other electronics within
the same panel.
The OEM has this liberty because CE is a machinery directive.
Whether or not every component in the OEM’s machinery meets
CE, the OEM must still submit his machine for CE approval.
meet CE, the machine will not necessarily meet CE as a
machine.