17
Voltage follower (MM21051C only)
Instead of using a speed adjust potentiometer, the drive may be
wired to follow an analog input voltage signal that is isolated from
earth ground (Figure 9). The range of this signal is 0 - 6 VDC.
Connect the signal input (+) to S2. Connect the signal common (–)
to S1. Make no connection to S3. A potentiometer can be used to
scale the analog input voltage. To achieve isolation, use an
interface device such as Minarik model PCM4 to scale the analog
input voltage.
Figure 9. Voltage Follower Connections
Installation
Summary of Contents for MM21051C
Page 9: ...3 Figure 2 MM21151C Dimensions ALL DIMENSIONS IN INCHES MM Dimensions...
Page 10: ...4 Dimensions Figure 3 MM21251C Dimensions ALL DIMENSIONS IN INCHES MM...
Page 11: ...5 Figure 4 MM21151C and MM21251C Back View Cased Mounting Keyhole Locations...
Page 31: ...25 Figure 12 Dynamic Braking Circuit Connection Operation...
Page 33: ...27 Calibration Figure 13 Calibration Trimpot Layouts MM21051C MM21151C MM21251C...
Page 50: ...44 Figure 23 MM21051C MM21151C and MM21251C block diagram Block Diagrams...
Page 51: ...45 Figure 24 MM21151C switching circuit connections...
Page 52: ...46 Block Diagrams Figure 25 MM21251C switching circuit connections...
Page 54: ...48 Notes...