![MIMAKI jV100-160 Requests For Care And Maintenance Download Page 9](http://html1.mh-extra.com/html/mimaki/jv100-160/jv100-160_requests-for-care-and-maintenance_1800244009.webp)
3. Maintenance
9
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Platen Right End ], then press the [ENTER] key.
• The carriage moves over the platen.
3
Open the front cover.
4
Clean the cap rubber.
• Wipe off any ink adhering with a clean stick moistened with maintenance liquid.
• Wipe off the maintenance liquid. Make sure none remains.
Cap rubber
5
Check to confirm that the cap slider is not tilted once cleaning is complete.
• If the cap slider is tilted, move the slider block to the left or right to correct the tilt.
6
Close the front cover, then press the [ENTER] key.
NCU Cleaning
The NCU uses a sensor to monitor the ink droplets ejected from the print head nozzles. Continuing to use
the dirty NCU may prevent the nozzle Check function from operating correctly.