3. Maintenance
14
l
Cleaning the carriage underside sensor
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Maint. Space], then press the [ENTER] key.
• The carriage moves to the maintenance space.
3
Open the maintenance cover.
4
Clean the media sensor.
5
Once cleaning is complete, close the maintenance covers, then press the [ENTER] key.
Automatic Correction Sensor (DAS) Cleaning
The DAS sensor is located on the carriage underside. If dust or debris accumulates on the sensor, an error
may occur in the automatic correction function (Automatic correction of drop position). Remove any debris
using cotton swabs or a soft cloth.
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Maint. Space], then press the [ENTER] key.
• The carriage moves to the maintenance space.
3
Open the maintenance cover.