2
Select [Station] > [Nozzle Wash], then press the [ENTER] key.
• The carriage moves over the platen.
3
Open the front cover.
4
Clean the wiper and bracket.
•
5
Press the [ENTER] key once cleaning is complete.
• “Cap Cleaning Completed (Next)[ENT]” appears on the display.
6
Clean the cap rubber.
•
7
Once cleaning is complete, close the front cover, then press the [ENTER] key.
• The cap is filled with maintenance liquid.
• Close the front cover. The cap cannot be filled with maintenance liquid unless the front
cover is closed. This is also true if the maintenance liquid cartridge is empty.
8
Open the front cover.
• Check to confirm that the cap is filled with maintenance liquid.
• If not, use a syringe to draw up some maintenance liquid and fill until it almost overflows
from the cap.
9
Close the front cover, then press the [ENTER] key.
10
Set the exposure time, then press the [ENTER] key.
• Print nozzle washing starts. The elapsed time is displayed on the display.
• Cleaning is performed automatically once print nozzle washing has ended.