3
FUNCTIONAL DESCRIPTION
1
3
4
2
6
8
10
7
1.
Head
2.
Extension poles
3.
Extension latches
4.
Switch
5.
Upper handle
6.
Leg release button
7.
Legs
8.
Carrying handle
9.
Battery bay
10.
AC inlet
9
5
ASSEMBLY
WARNING
Recharge only with the charger
specified for the battery. For spe
-
cific charging instructions, read the operator’s
manual supplied with your charger and battery.
Removing/Inserting the Battery
To
remove
the battery, push in the release buttons
and pull the battery pack away from the tool.
WARNING
Always lock the trigger or remove
the battery pack any time the tool
is not in use.
To
insert
the battery, slide the pack into the body
of the tool. Make sure it latches securely into place.
WARNING
Only use accessories specifically
recommended for this tool. Others
may be hazardous.
Inserting/Removing Extension Cord
To operate the light on AC power, extend and lock
legs. Plug a suitable extension cord into the AC
inlet
. To disconnect the extension cord, press the
switch
button to turn off the light, then remove the
cord from the inlet.
NOTE:
When an extension cord is plugged into the
light, the light will automatically run on AC power.
Recommended Minimum Wire Gauge
For Extension Cords*
Nameplate Amps
Extension Cord Length
25'
50'
75'
100'
150'
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 16.0
16.1 - 20.0
18
18
18
18
16
14
12
18
18
18
16
14
12
10
18
18
16
14
12
10
--
18
16
14
12
10
--
--
16
14
12
12
--
--
--
* Based on limiting the line voltage drop to five volts at 150%
of the rated amperes.
READ AND SAVE ALL INSTRUCTIONS
FOR FUTURE USE.
Double Insulated Tools (Two-Prong Plugs)
Tools marked “Double Insulated” do not require
grounding. They have a special double insulation
system which satisfies OSHA requirements and
complies with the applicable standards
Fig. A Fig. B
of Underwriters Laboratories, Inc., the
Canadian Standard Association and
the National Electrical Code. Double
Insulated tools may be used in either
of the 120 volt outlets shown in Figures
A and B.
SYMBOLOGY
Volts
Direct Current
Alternating Current
Amps
Double Insulated
AC Power
CAUTION
Bright Light - Do Not
Stare Into Light
1.
2.
Always extend legs before raising the
poles.
Keep hands clear of housing when
collapsing the extension poles.
Read operator’s manual.
C
US
UL Listing for Canada and U.S.
SPECIFICATIONS
Cat. No. ..................................................... 2131-20
Volts
..............................................................
18 DC
Battery Type
.................................................
M18™
Charger Type
................................................
M18™
AC Input Volts
....................................................
120
DC Input Volts
......................................................
18
AC Input Amps
....................................................0.5
Recommended Ambient
Operating Temperature .....................
0°F to 125°F