GENERAL POWER TOOL           

SAFETY WARNINGS

WARNING

Read all safety warnings, instruc-

tions, illustrations and specifica

-

tions provided with this power tool. 

Failure to 

follow all instructions listed below may result in 

electric  shock,  fire  and/or  serious  injury. 

Save all 

warnings and instructions for future reference. 

The term "power tool" in the warnings refers to your 

mains-operated (corded) power tool or battery-oper-

ated (cordless) power tool.

WORK AREA SAFETY

• Keep work area clean and well lit. 

Cluttered or 

dark areas invite accidents.

• Do not operate power tools in explosive atmo-

spheres, such as in the presence of flammable 

liquids, gases or dust. 

Power tools create sparks 

which may ignite the dust or fumes.

• 

Keep children and bystanders away while operating 

a power tool. 

Distractions can cause you to lose control.

ELECTRICAL SAFETY

• Power tool plugs must match the outlet. Never 

modify the plug in any way. Do not use any 

adapter plugs with earthed (grounded) power 

tools. 

Unmodified plugs and matching outlets will 

reduce risk of electric shock.

• 

Avoid body contact with earthed or grounded 

surfaces, such as pipes, radiators, ranges and 

refrigerators. 

There is an increased risk of electric 

shock if your body is earthed or grounded.

• Do not expose power tools to rain or wet condi-

tions. 

Water entering a power tool will increase the 

risk of electric shock.

• 

Do not abuse the cord. Never use the cord for 

carrying, pulling or unplugging the power tool. 

Keep cord away from heat, oil, sharp edges or 

moving parts. 

Damaged or entangled cords increase 

the risk of electric shock.

• When operating a power tool outdoors, use an ex-

tension cord suitable for outdoor use. 

Use of a cord 

suitable for outdoor use reduces the risk of electric shock.

• If operating a power tool in a damp location is 

unavoidable, use a ground fault circuit interrupter 

(GFCI) protected supply. 

Use of an GFCI reduces 

the risk of electric shock. 

PERSONAL SAFETY

• Stay alert, watch what you are doing and use 

common sense when operating a power tool. Do 

not use a power tool while you are tired or under 

the influence of drugs, alcohol or medication. 

moment of inattention while operating power tools 

may result in serious personal injury.

• 

Use  personal  protective  equipment.  Always 

wear eye protection. 

Protective equipment such 

as a dust mask, non-skid safety shoes, hard hat or 

hearing protection used for appropriate conditions 

will reduce personal injuries. 

• Prevent unintentional starting. Ensure the switch 

is in the off-position before connecting to power 

source and/or battery pack, picking up or carrying 

the tool. 

Carrying power tools with your finger on 

the switch or energizing power tools that have the 

switch on invites accidents.

• 

Remove  any  adjusting  key  or  wrench  before 

turning the power tool on.

 A wrench or a key left 

attached to a rotating part of the power tool may 

result in personal injury.

• Do not overreach. Keep proper footing and 

balance at all times. 

This enables better control 

of the power tool in unexpected situations.  

• Dress properly. Do not wear loose clothing or 

jewelry. Keep your hair and clothing away from 

moving parts. 

Loose clothes, jewelry or long hair 

can be caught in moving parts.

• If devices are provided for the connection of 

dust extraction and collection facilities, ensure 

these are connected and properly used. 

Use of 

dust collection can reduce dust-related hazards.

• 

Do not let familiarity gained from frequent use 

of tools allow you to become complacent and 

ignore tool safety principles. 

A careless action can 

cause severe injury within a fraction of a second.

POWER TOOL USE AND CARE

• Do not force the power tool. Use the correct power 

tool for your application. 

The correct power tool 

will do the job better and safer at the rate for which 

it was designed.

• Do not use the power tool if the switch does not turn 

it on and off. 

Any power tool that cannot be controlled 

with the switch is dangerous and must be repaired.

• Disconnect the plug from the power source and/

or remove the battery pack, if detachable, from 

the power tool before making any adjustments, 

changing accessories, or storing power tools. 

Such preventive safety measures reduce the risk of 

starting the power tool accidentally.

• Store idle power tools out of the reach of children 

and do not allow persons unfamiliar with the 

power tool or these instructions to operate the 

power tool. 

Power tools are dangerous in the hands 

of untrained users.  

• Maintain power tools and accessories. Check 

for misalignment or binding of moving parts, 

breakage of parts and any other condition that 

may affect the power tool’s operation. If damaged, 

have the power tool repaired before use. 

Many ac-

cidents are caused by poorly maintained power tools.

• Keep cutting tools sharp and clean. 

Properly 

maintained cutting tools with sharp cutting edges 

are less likely to bind and are easier to control.

• 

Use the power tool, accessories and tool bits 

etc. in accordance with these instructions, 

taking into account the working conditions and 

the work to be performed. 

Use of the power tool 

for operations different from those intended could 

result in a hazardous situation.

• Keep handles and grasping surfaces dry, clean 

and free from oil and grease. 

Slippery handles and 

grasping surfaces do not allow for safe handling and 

control of the tool in unexpected situations.

BATTERY TOOL USE AND CARE

• Recharge only with the charger specified by the 

manufacturer. 

A charger that is suitable for one type 

of battery pack may create a risk of fire when used 

with another battery pack.

• 

Use power tools only with specifically designated 

battery packs. 

Use of any other battery packs may 

create a risk of injury and fire.

• 

When battery pack is not in use, keep it away 

from other metal objects, like paper clips, coins, 

keys, nails, screws or other small metal objects, 

that can make a connection from one terminal 

to another. 

Shorting the battery terminals together 

may cause burns or a fire. 

Summary of Contents for MX FUEL MXF500

Page 1: ... must read and understand operator s manual AVERTISSEMENT Afin de réduire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de lesiones el usuario debe leer y entender el manual WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de réduire le risque de blessures l utilisateur doit lire ...

Page 2: ...ry Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected situations Dress properly Do not wear loose clothing or jewelry Keep your hair and clothing away from moving parts Loose clothes jewelry or long hair can be caught in moving parts If devices are provided for the connection of dust extraction and collection facilities ensure ...

Page 3: ...the drain the size s and length s of the drain distance to mainlines the nature of the blockage presence of drain cleaning chemicals or other chemicals etc If chemicals are present in the drain it is important to understand the specific safety measures required to work around those chemicals Contact the chemical manufacturer for required information If needed place protective covers in the work ar...

Page 4: ...nded Pipe Diameter 3 8 Foot Pedal Cat No 14 02 0000 Cat No MXF500 Weight without cable 110 lbs Cat No MXF501 Weight without cable 120 lbs FUNCTIONAL DESCRIPTION 8 1 Transport handle 2 Control panel 3 Wheels 4 Stand 5 Drum latches 6 Drum plug 7 Stand Lower lift handle 8 Cable 9 Cable feed handle 10 Cable feed quick release button 11 Cable feed ratchet lever 12 Drum 13 Battery bay 14 Foot pedal cord...

Page 5: ...87 1 Always wear leather gloves over latex rubber gloves to avoid entangle ment Cable tip may be sharp Never feed more than 100 of cable into the machine to avoid overloading Remove the cable for cleaning after each use Differ ent size and types of cables are available for different applications The instructions below detail how to remove install the cable manually NOTE The cable feed can also be ...

Page 6: ...MXF501 POWERTREDZ lift assist Always clear the area of obstructions before use Loss of control could cause injury Using lift assist is one person operation Use the POWERTREDZ lift assist to move the machine up and down stairs into or out of a work vehicle etc NOTE The POWERTREDZ lift assist will not engage if there is insufficient battery life left to ascend descend a standard flight of stairs To ...

Page 7: ...sting If it becomes necessary to hoist the machine use the center of the transport handle as the anchor point Ensure the hoisting strap will not slip or con tact other parts such as the POWERTREDZTM lift assist trigger Drain Cleaning Setup 1 Place the sewer drum machine no further than 2 from the drain WARNING Greater distance can cause twisting kinking breaking or whipping of the cable 2 Remove t...

Page 8: ...n the center locked position Always lock the switch or remove the battery pack before performing maintenance changing accessories storing the machine and any time the machine is not in use Starting and Stopping Speed 1 To start the machine push the Forward OFF Reverse switch to Forward and step or kneel on the foot pedal 2 To stop the machine release pressure on the pedal Then push the Forward OFF...

Page 9: ...air After six months to one year depending on use return the machine battery pack and charger to a MILWAUKEE service facility for inspection If the machine does not start or operate at full power with a fully charged battery pack clean the contacts on the battery pack If the machine still does not work properly return the machine charger and battery pack to a MILWAUKEE service facility for repairs...

Page 10: ...ough the nose of the cable feed by hand Do not turn on the machine 7 Feed the new anchor cable in through the nose of the cable feed by hand Do not turn on the machine 8 Ensure the cable is following the curve of the feed tube when lying in the drum 9 Align the anchor cable with the stop and insert the 1 4 20 bolt Thread the 1 4 20 nut onto the bolt and tighten securely 10 Realign the front and re...

Page 11: ...a different manner from the end user guide or instruction manual b When the conditions of use are not normal c When the product was modified or repaired by people not authorized by TECHTRONIC INDUSTRIES Note If cord set is damaged it should be replaced by an Authorized Service Center to avoid electric risks SERVICE AND ATTENTION CENTER Call to 55 4160 3547 IMPORTED AND COMMERCIALIZED BY TECHTRONIC...

Page 12: ...oblème risque d affecter le bon fonctionnement de l outil En cas de dommages faire réparer l outil avant de l utiliser Plusieurs accidents sont causés par des produits mal entretenus Garder les outils bien affûtés et propres Des outils correctement entretenus et dont les tranchants sont bien affûtés risquent moins de se bloquer et sont plus faciles à contrôler Utiliser l outil électrique les acces...

Page 13: ...re de travail si nécessaire Le processus de nettoyage de drains peut être ennuyeux Veuillez s assurer que le câble s est totalement rétracté à l intérieur du nettoyeur de drains Ceci évitera qu il n y ait une surliure durant le démarrage Mettre le nettoyeur de drain à une distance maximale de soixante centimètres deux pieds par rapport à l orifice du drain Si le nettoyeur de drain ne peut pas être...

Page 14: ...ÉCAUTION Risque de décharge électrique Lire le manuel d utilisation Toujours porter gants en cuir sur du latex ou des gants en caoutchouc Toujours porter une protection oculaire Porter une protection respiratoire et auditive appropriée Soulever à deux personnes Levage auxiliaire Nettoyage de drains Montée Descente o Contrôle de marche avant ARRÊT marche arrière du tambour C US UL Listing Mark pour...

Page 15: ...ulaire appropriée certifiée conforme à la norme ANSI Z87 1 Toujours porter gants sur du latex ou des gants en caoutchouc pour éviter l enchevêtrement La pointe du câble pourra bien être tranchante Ne jamais alimenter la machine avec plus de 30 m 100 de câble afin d éviter une surcharge Retirer le câble après chaque usage pour le net toyer Il y a une haute gamme de tailles et types différents de câ...

Page 16: ...r la machine à une personne dans une camion nette ou sur la plateforme d un camion Levage auxiliaire POWERTREDZ Modèle MXF501 uniquement AVERTISSEMENT Ne laisser personne s approcher lors de l utilisation du levage auxiliaire MXF501 POWERTREDZ Toujours s assurer d avoir un chemin de passage sans obstructions avant l utilisation La perte de contrôle peut causer des blessures L utilisation du levage...

Page 17: ...pression descendante lors que vous tirez la machine vers le haut Poussée Tirer MAX 56 cm 22 10 Une fois vous êtes arrivé à un palier tirer sur la machine pour engager las roulettes 11 Lors de la descente laisser les roulettes franchir le bord pour engager les chapes Maintenir l angle d inclinaison et pousser la poignée vers le bas sur la surface Laisser le levage auxiliaire vous aider à déplacer l...

Page 18: ...5 minutes d inactivité la machine entrera en mode de veille L icône MX FUEL s éteindra et la gâchette et les voyants à DEL seront ino pérants 4 Appuyer et tenir enfoncé le bouton d armement durant 1 seconde pour réactiver la machine 5 Appuyer et tenir enfoncé le bouton d armement durant 1 seconde pour désarmer éteindre la machine L icône MX FUEL s éteindra Utilisation du commutateur marche avant A...

Page 19: ...e d ancrage Il faut donc charger la machine avec plus de câble et les relier ou bien relier le câble original à celui d une autre machine AVERTISSEMENT Ne jamais alimenter la machine avec plus de 30 m 100 de câble afin d éviter une surcharge 6 Au moment où on a atteint l obstruction désen gager l alimentation automatique Bouger le câble d un mouvement va et vient jusqu à ce que l obstruction soit ...

Page 20: ...n le sens correct des pôles positif et négatif 5 Fermer la porte du compartiment de la pile et ser rer la vis fermement AVERTISSEMENT Pourminimiserlesrisques de blessures ou de dom mages à l outil n immergez jamais l outil la bat terie ou le chargeur et ne laissez pas de liquide s y infiltrer Nettoyage Débarrassez les évents des débris et de la poussière Gardez les poignées propres à sec et exempt...

Page 21: ...rée le plus proche ACCESOIRES AVERTISSEMENT L utilisation d autres ac cessoires que ceux qui sont spécifiquement recommandés pour cet outil peut comporter des risques Pour une liste complète des accessoires visiter le site internet www milwaukeetool com ou contactez un distributeur SERVICE CANADA Milwaukee Tool Canada Ltd 1 800 268 4015 Monday Friday 7 00 AM 4 30 PM CST www milwaukeetool ca GARANT...

Page 22: ... DE RÉPARATIONS ET DE SERVICE Composer le 55 4160 3547 IMPORTÉ ET COMMERCIALISÉ PAR TECHTRONIC INDUSTRIES MEXIQUE S A DE C V Miguel de Cervantes Saavedra No 301 Piso 5 Torre Norte 11520 Colonia Ampliación Granada Miguel Hidalgo Ciudad de Mexico Mexico Modèle Date d achat Sceau du distributeur ou du magasin ADVERTENCIAS DE SEGURIDAD GENERALES PARA LA HERRAMIENTA ELÉCTRICA ADVERTENCIA Lea todas las ...

Page 23: ...ue no estén familiarizadas con la herramienta eléctrica o con estas instruc ciones la utilicen Las herramientas eléctricas son peligrosas en manos de usuarios sin capacitación Dé mantenimiento a las herramientas eléctricas y accesorios Verifique que no haya desalin eación amarre de partes móviles partes rotas o alguna otra condición que pueda afectar el funcionamiento de la herramienta eléctrica S...

Page 24: ... drenaje a una distancia menor a 61 cm dos pies de la abertura del drenaje Si el limpiador de drenaje no puede colocarse en una distancia de 61 cm dos pies de la abertura del drenaje esta necesitará extenderse usando una tu bería y conexiones de tamaño similar Las distancias más grandes pueden causar problemas de control que provoquen que el cable se doble tuerza rompa o azote No opere el limpiado...

Page 25: ...renajes Ascender Descender o Control del tambor para avanzar apagado reversa C US UL Listing Mark para Canadá y Estados Unidos DESCRIPCION FUNCIONAL 8 1 Mango de transporte 2 Panel de control 3 Ruedas 4 Soporte 5 Pestillos del tambor 6 Tapón del tambor 7 Mango de elevación del soporte descenso 8 Cable 9 Empuñadura de alimentación de cable 10 Botón de liberación rápida para alimentar el cable 11 Pa...

Page 26: ...iesgo de lesiones siempre utilice la protección de ojos adecuada indicada para cumplir con lo dispuesto en la norma ANSI Z87 1 Siempre utilice guantes de cuero sobre el látex o guantes de goma para evitar el enredo La punta del cable puede estar filosa Nunca ali mente más de 30 m 100 de cable en la máquina para evitar una sobrecarga Retire el cable para limpiar después de cada uso Están disponible...

Page 27: ...s del uso La pérdida de control puede provocar lesiones El uso del asistente de elevación es una operación a efectuarse por una sola persona Use del asistente de elevación POWERTREDZ para ayudarle a mover la máquina por las escaleras ya sea hacia arriba o hacia abajo así como para me terla o sacarla de un vehículo de trabajo etc NOTA El asistente de elevación POWERTREDZ no se activará si no tiene ...

Page 28: ...e necesario usar aparejos para subir la máquina utilice el centro del mango de transportación como punto de anclaje Asegúrese de que la correa de elevación no se resbale ni esté en contacto con ninguna otra pieza como el gatillo del asistente de elevación POWERTREDZ Configuración de limpieza de drenaje 1 Coloque la máquina de tambores para drenajes a una distancia máxima de 61 cm 2 en relación con...

Page 29: ...ción de reversa para despejar el cable atas cado No utilice la función de reversa para retraer el cable 3 Para apagar la función de rotación y bloquear el interruptor gire el interruptor de avance apagado reversa hacia la posición central O El pedal no funcionará mientras el interruptor de avance apagado reversa se encuentre en la posición de bloqueo Siempre bloquee el interruptor o quite la bater...

Page 30: ...lugar conveniente 5 Antes de guardar la máquina lave el cable y el tambor consulte la sección de Limpieza de cables y tambor en la parte de Mantenimiento MANTENIMIENTO ADVERTENCIA Para reducir el riesgo de una lesión desconecte siempre la herramienta antes de darle cualquier manten imiento Nunca desarme la herramienta ni trate de hacer modificaciones en el sistema eléctrico de la misma Acuda siemp...

Page 31: ...se asiente el aceite 7 Repita el proceso después de cada uso Limpieza de cables y tambores El cable y el tambor deben enjuagarse minuciosa mente con agua después de haberlos usado cada vez con el fin de evitar los efectos dañinos de los sedimentos y los compuestos de limpieza de dre najes ADVERTENCIA Siempre utilice guantes de cuero sobre el látex o guantes de goma para evitar el enredo Después de...

Page 32: ...ONDICIÓN DEL CONTRATO PARA LA COMPRA DE TODO PRO DUCTO DE MILWAUKEE SI USTED NOACEPTAESTACONDICIÓN NO DEBE COMPRAR EL PRODUCTO MILWAUKEE NO SERÁ RESPONSABLE EN NINGÚN CASO DE DAÑOS INCIDENTALES ESPECIALES EMERGENTES O PUNITIVOS NI DE NINGÚN COSTO HONORARIOS LEGALES GASTOS PÉRDIDAS O DE MORAS ALEGADOS COMO CONSECUENCIA DE ALGÚN DAÑO FALLA O DEFECTO EN NINGÚN PRODUCTO INCLUYENDO ENTRE OTROS RECLAMAC...