Switching sides for the Depth Gauge

4.

1. Turn 

OFF

 the tool.

2. Remove the battery pack.

3. Remove the depth stop (see "Removing/Installing

the Depth Stop").

5.

6.

7.

Remove the screw attaching the front depth brack-

et to the ruler assembly with a philips screwdriver.

the bottom plate of the ruler assembly out of the

front button, this may require both buttons to be

pushed at the same time.

Remove the rear depth bracket from the ruler as-

sembly and reassemble it so the bracket hangs

on the desired side.

Slide the bottom ruler plate through the top button 

(the reverse of step 5).

8. Reattach the bit depth gauge button, the top

small tabs.

9. Install the depth stop (see "Removing/Installing

the Depth Stop").

Attaching the HAMMERVAC™ to the

Rotary Hammer

These HAMMERVAC™ Dust Extractors are for use 

with dedicated rotary hammers. Refer to the Speci-

1. Remove the battery pack from the rotary hammer.

2. Slide the foot of the rotary hammer onto the dust

extractor.

3. Push the contacts through the protective cover

on the rotary hammer. The hammer release will

snap into place.

Installing/Removing the Bit

Fitting the HAMMERVAC™ 

to the Tool and Bit

Correct

Incorrect

Incorrect

depth gauge button. 

For proper suction and depth

control, position the nozzle as-

forward face of the nozzle:

1. Press and hold the tool and bit 

2. Push in the nozzle assembly

front face of the nozzle.

3. Release the tool and bit depth

gauge button.

N O T E :

  F u l l y   e x t e n d   t h e 

HAMMERVAC™ before storing 

to preserve spring life. 

Setting the Drilling Depth

1. Fit the HAMMERVAC™ to the tool and bit.

2. Press and hold the depth gauge button and slide

the depth gauge to the desired depth. The drilling 

depth is the last visible measurement shown when 

viewed from the depth gauge on the top of the

tool. To ensure the HAMMERVAC™ is properly

set to the tool, bit, and desired depth, always drill

a test hole.

Depth

Drill 

NOTE: 

When using the optional Crevice Tool

(Cat. No. 49902325), set the drill depth to 0.

Slide the bit through the nozzle and then install into 

the tool according to the tool manufacturer's 

instructions. For best results, use a bit 203 mm (8") 

in length or shorter for M18 FDEX and use a bit 

254 mm (10") in length or shorter for  M18 FPDEX.

Summary of Contents for M18 FDEX

Page 1: ...OPERATOR S MANUAL Cat No M18 FDEX M18 FPDEX WARNING To reduce the risk of injury user must read and understand operator s manual M18 FUELTM HAMMERVACTM 26 MM 28 MM DEDICATED DUST EXTRACTORS ...

Page 2: ...uch as cigarettes matches or hot ashes Do not pick up soot cement plaster or drywall motor or be exhausted back into the air Use special care when emptying heavily loaded tanks To avoid spontaneous combustion empty dust box after each use Do not leave dust extractor unattended when battery pack is installed Remove battery pack when not in use and before servicing Disconnect the battery pack from t...

Page 3: ...these chemicals work in a well ventilated area and work with approved safety equipment such as those dust masks that are specially designed to 9 8 1 Hammer contacts 2 Depth gauge 3 Nozzle adjustment lever 4 Nozzle 5 Bit brush 6 Bit depth gauge button 7 8 Dust box latches 9 Hammer release button 4 3 2 5 8 6 1 7 FUNCTIONAL DESCRIPTION READ AND SAVE ALL INSTRUCTIONS FOR FUTURE USE To reduce the risk ...

Page 4: ...o place NOTE Do not operate the HAMMERVAC without Installing Removing Nozzle Replace the nozzle After drilling about 1500 holes When the bit brush shows signs of wear When suction is reduced When dust escapes through the bit brush during use To replace the Standard Cat No 14520105 and Large Cat No 14520110 nozzles rotate the nozzle release lever down to the open position and pull out nozzle from t...

Page 5: ... cover on the rotary hammer The hammer release will snap into place Installing Removing the Bit Fitting the HAMMERVAC to the Tool and Bit Correct Incorrect Incorrect depth gauge button For proper suction and depth control position the nozzle as forward face of the nozzle 1 Press and hold the tool and bit 2 Push in the nozzle assembly front face of the nozzle 3 Release the tool and bit depth gauge ...

Page 6: ...lding away from the user s face and tapping dust box into a bin or other reasonable container For best cleaning results connect a vacuum hose with dust extraction adapter Cat No 49901959 to the dust box port and suction out debris Pull the HEPA filter away from the dust box and tap clean Do not clean with water or compressed air After about 1500 holes or loss of suction discard and replace HEPA fi...

Page 7: ......

Page 8: ...alia Toll Free Telephone Number 1300 645 928 New Zealand Toll Free Telephone Number 0800 645 928 or visit milwaukeetool com au milwaukeetool co nz Please refer to Australian and New Zealand warranty supplied with tool This warranty applies only to product sold by authorised dealers in Australia and New Zealand 961013962 01 A Milwaukee Electric Tool Corporation 13135 West Lisbon Road Brookfield Wis...

Reviews: