background image

5

 

NOTE:

 If the current pressure item to be inflated 

is greater than the target pressure, the tool will not 

begin inflation.

7. To start, press the Inflation  

  button. The 

minimum setting for the automatic stop feature is 

10 PSI. 

8. The tool will shut off automatically once the target 

pressure has been reached. 

 

NOTE:

 Inflation may continue after Auto Pressure 

Check Feature is engaged to hit the most accurate 

results.

 

NOTICE: 

To avoid tool damage from overheating, 

allow tool to cool for 40 minutes after each 20 minutes 

of continuous use.

9. To stop, press the Inflation 

 button or power 

button. 

NOTE:

 The tool will shut down after 5 minutes of 

inactivity. 

NOTE:

 The tool's cooling fan will run until the pump 

head cools or the tool is turned off. 

MEMORY

UNITS

Manual Inflate

The  inflator  can  also  be  used  to  manually  inflate 

items.  When  a  target  input  value  is  not  set,  the 

inflator will show 0 PSI.  Press and hold the inflation 

button until desired pressure is reached.  When the 

inflation  button  is  released,  inflation  will  stop.  For 

small inflatables and bike tires it is recommended to 

use manual inflate mode for most accurate results.

NOTE:

 For anything under 10 PSI, manually inflate 

the item using the manual Inflate mode.

Memory Settings

To view memory settings, press the memory button 

to  navigate  through  memory  slots  M1  -  M4. After 

reaching memory slot M4, pressing the memory 

button again will return to the homescreen.

To adjust memory settings:

1. 

Press the memory button to navigate to the desired 

M1 - M4 memory slot. 

2. 

Press     or  

 to adjust to the desired inflation 

value.

3. 

Press and hold the memory button for 2 seconds 

to store the pressure in the current memory slot.  

To inflate to a saved memory setting:

1. 

Press the memory button  to navigate to the de-

sired M1 - M4 memory slot. 

2. Press the inflation button.

NOTE: 

The actual value indicator will increase until 

it reaches the saved memory value.  

Troubleshooting

If pressure accuracy becomes poor or the inflator's 

actual value reads greater than zero when not con-

nected to any object, the pressure sensor may have 

drifted due to altitude or other factors. 

To re-zero: 

With nothing connected to the inflator, hold 

the  

  and the Inflation  

  button for 3 seconds 

to re-zero the pressure.

NOTE

: This function will re-zero up to 5 PSI.

Sports Needle/Raft Nozzle

Insert needle or nozzle onto the inflator. Attach to the 

item. Be careful not to bend the accessory. Remove 

after inflation.

Presta Valve

Use the Presta valve with Presta valve stems. Before 

inflating, loosen the locking nut on the valve stem. 

Once inflation is complete, tighten the locking nut to 

seal the valve.

MAINTENANCE

WARNING

To reduce the risk of injury, always 

unplug the charger and remove the 

battery  pack  from  the  charger  or  tool  before 

performing any maintenance. Never disassemble 

the  tool,  battery  pack  or  charger.  Contact  a 

MILWAUKEE service facility for ALL repairs.

Maintaining Tool 

Keep your tool, battery pack and charger in good 

repair by adopting a regular maintenance program. 

Inspect your tool for issues such as undue noise, 

misalignment or binding of moving parts, breakage of 

parts, or any other condition that may affect the tool 

operation. Return the tool, battery pack, and charger 

to a MILWAUKEE service facility for repair. After six 

months to one year, depending on use, return the 

tool, battery pack and charger to a MILWAUKEE 

service facility for inspection.

If the tool does not start or operate at full power with 

a fully charged battery pack, clean the contacts on 

the battery pack. If the tool still does not work prop

-

erly, return the tool, charger and battery pack, to a 

MILWAUKEE service facility for repairs.

WARNING

To reduce the risk of personal in-

jury and damage, never immerse 

your tool, battery pack or charger in liquid or 

allow a liquid to flow inside them.

Cleaning

Clean  dust  and  debris  from  any  vents.  Keep  tool 

clean, dry and free of oil or grease. Use only mild 

soap and a damp cloth to clean, since certain clean-

ing agents and solvents are harmful to plastics and 

other insulated parts. Some of these include gasoline, 

turpentine, lacquer thinner, paint thinner, chlorinated 

cleaning solvents, ammonia and household deter-

gents containing ammonia. Never use flammable or 

combustible solvents around tools.

Repairs

For repairs, return the tool, battery pack and charger 

to the nearest authorized service center.

ACCESSORIES

WARNING

Use only recommended accesso-

ries. Others may be hazardous.

For a complete listing of accessories, go online to 

www.milwaukeetool.com or contact a distributor.

SERVICE - UNITED STATES

1-800-SAWDUST

 

(1.800.729.3878)

Monday-Friday, 7:00 AM - 6:30 PM CST

or visit 

www.milwaukeetool.com

Contact Corporate After Sales Service Technical 

Support  with  technical,  service/repair,  or  warranty 

questions. 
Email: [email protected]

Become a Heavy Duty Club Member at 

www.milwaukeetool.com  to  receive  important 

notifications regarding your tool purchases. 

SERVICE - CANADA

Milwaukee Tool (Canada) Ltd 

1.800.268.4015

Monday-Friday, 7:00 AM - 4:30 PM CST

or visit 

www.milwaukeetool.ca

Summary of Contents for M18 2848-20

Page 1: ...e risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de lesiones el usuario debe leer y entender el manual WARNING To reduce the risk of injury...

Page 2: ...y or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury Do not overreach Keep proper footing and balance at all...

Page 3: ...er than marked maximum pressure of item to be inflated Use only recommended MILWAUKEE inflator accessories Others may be hazardous Neverblockorplugtheairoutletduringoperation Never carry tool by the a...

Page 4: ...ro priate respiratory protection or use an OSHA compliant dust extraction solution Do not leave the tool unattended during operation Risk of Bursting Do not overinflate Follow all manufacturer s instr...

Page 5: ...on Presta Valve Use the Presta valve with Presta valve stems Before inflating loosen the locking nut on the valve stem Once inflation is complete tighten the locking nut to seal the valve MAINTENANCE...

Page 6: ...IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES WRITTEN OR ORAL TO THE EXTENT PERMITTED BY LAW MILWAUKEE DISCLAIMS ANY IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF...

Page 7: ...bl me risque d affecter le bon fonctionnement de l outil En cas de dommages faire r parer l outil avant de l utiliser Plusieurs accidents sont caus s par des produits mal entretenus Garder les outils...

Page 8: ...xtraction de poussi re conforme aux normes OSHA Toujours faire preuve de bons sens et proc der avec prudence lors de l utilisation d outils C est impossible de pr voir toutes les situations dont le r...

Page 9: ...gonfler pour obtenir les r sultats les plus pr cis La fonction de v rification automatique de pression pourra s engager jusqu 5 fois Une fois achev le PSI cible le gonfleur s arr tera automatiquement...

Page 10: ...onflage durant 3 secondes pour remettre la pression z ro REMARQUE Cette fonction se remettra une puissance de 5 PSI Aiguille sportive embout pour radeaux Ins rer l aiguille ou l embout sur le gonfleur...

Page 11: ...EZ PAS CETTE CONDITION VOUS NE DEVEZ PAS ACHETER LE PRODUIT EN AUCUN CAS MILWAUKEE NE SAURAIT TRE RESPONSABLE DE TOUT DOM MAGE ACCESSOIRE SP CIAL OU INDIRECT DE DOMMAGES INT R TS PUNITIFS OU DE TOUTE...

Page 12: ...eventivas de seguridad disminuyen el riesgo de que la herramienta el ctrica se encienda accidentalmente Almacene las herramientas el ctricas que no se est nutilizandofueradelalcancedelosni osyno permi...

Page 13: ...ara reducir el riesgo de lesiones al momento de realizar trabajos en situaciones donde haya presencia de polvo utilice la protecci n respira toria adecuada o utilice una soluci n de extrac ci n de pol...

Page 14: ...que se estabilice la presi n y posteriormente revisar la presi n en el sistema Al terminar de revisar la presi n en el sistema si no se ha llegado al PSI previsto continuar inflando para arrojar los...

Page 15: ...o est conectado a ning n objeto el sen sor de presi n podr a haber sufrido una desviaci n debido a la altitud o a otros factores Para restablecerse a cero Sin tener nada conectado al inflador mantenga...

Page 16: ...equiere el registro de la garant a para obtener la garant a cor respondiente a un producto de herramienta el ctrica de MILWAUKEE La fecha de manufactura del producto se utilizar para determinar el per...

Reviews: