background image

4

• free of vibrations

• 90° to the work area

2. Turn on the tool.

3. The tool will self-level when placed on surfaces 

within 4 degrees of true level when dial is unlocked 

and on.

4. The tool is ready once the emitted lines are con-

tinuous and no longer moving on the work surface.

5. If the tool cannot achieve a level state (i.e., the 

work surface is > 4 degrees off true level), the laser 

beams will flash rapidly (3 flashes per second). 

Relocate or adjust the work surface.

Troubleshooting

If the tool does not turn on:

• Ensure battery is installed properly.  Fuel gauge 

should indicate remaining charge when correctly 

installed.

• Ensure battery is charged.

• Ensure the tool's internal temperature is within 

specified operating ranges.  If stored in excessive 

heat or cold, allow at least 2 hours to acclimate to 

ambient temperature before turning on the tool.

If problem persists, please contact a MILWAUKEE 

service facility for support.

ACCURACY FIELD CHECK

NOTICE

Perform the Accuracy Field Check 

procedure immediately upon unboxing 

of each new Laser Level and before exposure to 

jobsite conditions. See "Accuracy Field Check" 

for information. 

Should any deviation from listed 

product accuracy be found, please con-

tact a MILWAUKEE service facility.  Failure to do so 

could result in rejection of warranty claim.

Influences on Accuracy

Ambient temperature gradients can impact laser 

accuracy.  For accurate and repeatable results, the 

following procedure should be conducted with the 

laser elevated off the ground and placed in the center 

of the working area. 

Abusive treatment of the Laser Level, such as exces-

sive impacts from drop, can also lead to deviations 

in product accuracy.  

Therefore, it is recommended to conduct the Field 

Check procedure after any impact or before complet-

ing any critical jobs.

Horizontal Height Accuracy

A free measuring distance of approximately 66' on a 

firm surface between two walls or structures A and 

B is required for this check.

It is also suggested to mount the Laser Level to a 

Tripod for easy adjustment. 

1. Securely mount the tool within 1' of wall A. 

 

A

B

 

1'

66'

WARNING

To reduce the risk of injury or dam-

age, securely mount/attach the 

laser before starting an operation. Injury/damage 

may occur if the laser falls.

Mounting/Adjusting the Laser Level

The pivot bracket can be used to mount the laser 

level in multiple ways:

• Use the embedded magnets to secure the laser level 

to steel studs, steel beams, etc.

• Use the keyhole slot to hang the laser level on the 

wall with a nail or screw.

• Set the laser level on a flat surface.

• Position  the  laser  and/or  wall  mount  on  a  stable 

surface. 

• Use the 1/4"-20  or 5/8"-11 threaded insert to mount 

on a tripod. 

• Once the level is mounted, use the micro adjustment 

knobs to fine tune the laser line.

OPERATION

WARNING

To reduce the risk of injury or tem-

porary  effects  on  vision,  do  not 

look directly into the laser when it is on.

CAUTION

Use of controls or adjustments or 

performance of procedures other 

than those specified herein may result in hazard

-

ous radiation exposure.

NOTICE

Perform the Accuracy Field Check 

procedure immediately upon unboxing 

of each new Laser Level and before exposure to 

jobsite conditions. See "Accuracy Field Check" 

for information.

Turning On/Off

To turn on the laser and unlock the pendulum, rotate 

the On/Off dial to the desired position. The remaining 

battery life will be displayed. 

WARNING!

 Do not look 

directly into laser apertures. Laser Mode Indicator 

LED will display, and horizontal level line will imme-

diately be emitted from aperture in the laser housing.

 ON 

Turns ON the laser and unlocks the pendu-

lum to enable self-leveling. 

 

ON 

Turns ON the laser but does not unlock the 

pendulum  (self  leveling  is  disabled). The 

laser lines will flash once every 8 seconds 

to indicate that the projected lines are not 

level or plumb.

  

NOTICE:

 The   ON mode disables self-

leveling and therefore is not intended for 

projecting a level or plumb line.  

 

OFF

   Turns OFF the laser and locks the pen-

dulum. When not in use, turn off the tool 

and store the Laser Level in the protective 

carrying case.

Use the MODE button to cycle through the three 

laser modes: 

    Horizontal Level Line
 

  Vertical Plumb Line & Plumb Points

    Perpendicular Level & Plumb Points 

The green laser mode indicators will display the 

selected mode. 

Using the Laser Level

1. For best results, place the tool on a work surface 

that is:

• sturdy

• 

level (within 4 degrees of true level)

Summary of Contents for M12 Series

Page 1: ...erator s manual AVERTISSEMENT Afin de réduire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de lesiones el usuario debe leer y entender el manual WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de réduire le risque de blessures l utilisateur doit lire et bien comprendre le manuel...

Page 2: ... explosion Followallcharginginstructionsanddonotcharge the battery pack or tool outside the temperature range specified in the instructions Charging improperly or at temperatures outside the specified range may damage the battery and increase the risk of fire STORE YOUR BATTERYAND TOOL in a cool dry place Do not store battery where temperatures may exceed 120 F 50 C such as in direct sunlight a ve...

Page 3: ...the Battery To remove the battery push in the release buttons and pull the battery pack away from the tool WARNING Always remove battery pack before changing or removing accessories To insert the battery slide the pack into the body of the tool Make sure it latches securely into place WARNING Only use accessories specifically recommended for this tool Others may be hazardous Power Save Use power s...

Page 4: ...e risk of injury or dam age securely mount attach the laser before starting an operation Injury damage may occur if the laser falls Mounting Adjusting the Laser Level The pivot bracket can be used to mount the laser level in multiple ways Use the embedded magnets to secure the laser level to steel studs steel beams etc Use the keyhole slot to hang the laser level on the wall with a nail or screw S...

Page 5: ...e of approximately 33 x33 on a firm surface between two walls or structures A and B is required for the check It is also suggested to mount the Laser Level to a Tripod for easy adjustment Securely mount the tool on one side of the room and centered between walls A and B Direct the laser lines toward the other side of the room such that the horizontal line appears on both walls A and B Allow the la...

Page 6: ... should not exceed 0 05 in a 7 doorway Plumb Dot Accuracy A free measuring distance of approximately 16 5 between floor and ceiling on a firm surface is required for this check It is suggested to install riser block if not already equipped 1 Place the tool within 1 of the floor 2 Turn the tool to ON and to Vertical Plumb Line Mode or Perpendicular Level Plumb Point Mode 3 Set tool on ground and ma...

Page 7: ...ree 3 years from the date of purchase The warranty period for the LED in the LED Work Light and the LED Upgrade Bulb for the Work Light is the lifetime of the product subject to the limitations above If during normal use the LED or LED Bulb fails the part will be replaced free of charge Warranty Registration is not necessary to obtain the applicable war ranty on a MILWAUKEE power tool product The ...

Page 8: ...e dans l outil ou bien si l outil est tombé mal utilisé ou modifié Ne pas se débarrasser de l outil et des batteries en les mettant avec les déchets ménagers L outil et les batteries qui ont atteint leur durée de vie utile devront être ramassés indépendamment pour les retourner à une installation de recyclage respectueuse de l environnement Veuillez s assurer que les aimants de l outil soient bien...

Page 9: ...st fixée solidement AVERTISSEMENT L emploi d accessoires autres que ceux qui sont expressément recommandés pour cet outil peut comporter des risques Économie d énergie Se servir du mode d économie d énergie pour pro longer l autonomie de la pile Le mode d économie d énergie est affiché par de faisceaux plus faibles et la pulsation du témoin de Mode La plage visuelle est mineure dans le mode d écon...

Page 10: ...nivelée environ 4 degrés du niveau réel exempte de vibrations 90 vers l aire de travail 2 Allumer l outil et appuyer sur les boutons de sélec tion de plan désiré 3 L outil parviendra à se mettre de niveau automa tiquement lorsqu il est placé sur de surfaces au près de 4 degrés du niveau réel lorsque le cadran est déverrouillé et activé 4 L outil sera prêt une fois que les lignes émises sont contin...

Page 11: ... d de hauteur de l outil Cette distance ne devra pas dépasser 6 mm 1 8 max à 91 cm 3 13 mm 1 2 à 40 m 132 Par rapport à la distance de mesure de 2 x 20 m 66 x 40 m 132 la déviation maximale per mise d est 40 m 132 x 6 mm 1 8 10 m 33 13 mm 1 2 Précision de nivellement horizontal Pour effectuer cette vérification une jauge d espace de mesure approximative de 10 m x 10 m 33 x 33 dans une surface firm...

Page 12: ...I à une distance de 2 4 m 8 au delà de l ouverture de la porte point II et sur le bord supérieur de celle ci point III 2 4m 8 2 4m 8 2 1m 7 5 Déplacer le niveau laser directement en arrière du point II sur l autre côté de la porte Aligner la ligne du laser vertical d une façon telle que le centre soit directement aligné sur les points I et II 6 Marquer le centre de la ligne verticale sur le rebord...

Page 13: ... 5 ans à compter de la date d achat sauf indication contraire Retourner l outil électrique à un centre de réparation en usine MILWAUKEE ou à un poste d entretien agréé MILWAUKEE en port prépayé et assuré Une copie de la preuve d achat doit être présentée lors du retour du produit Cette garantie ne couvre pas les dommages que MILWAUKEE détermine être causés par des réparations ou des tentatives de ...

Page 14: ...nes en carreteras obras de construcción etc Evite los entornos peligrosos Evite la exposición prolongada en la lluvia nieve o lugares húmedos o mojados No se use en presencia de atmósferas explosivas vapores gaseosos polvo o materiales inflamables SEGURIDAD PERSONAL Nopermitaqueoperenestaherramientapersonas que no estén familiarizadas con el aparato estas instrucciones de seguridad y el manual del...

Page 15: ...na instalación en particular Si este equipo ocasiona interferencia nociva con la recep ción de radio o televisión que pueda determinarse encendiendo y apagando el equipo se anima al usuario a intentar corregir la interferencia mediante una o más de las siguientes medidas Reorientar o reubicar la antena receptora Aumentar la distancia entre el equipo y el receptor Consulte al distribuidor o a un té...

Page 16: ...siones si el láser se cae Montar o ajustar el nivel láser El soporte del pivote puede usarse para montar el nivel láser de varias maneras Utilice los imanes incrustados para fijar el nivel láser a los montantes de acero vigas de acero etc Utilice la ranura de bocallave para colgar el nivel láser en la pared con un clavo o tornillo Coloque el nivel láser en una superficie plana Posiciones el láser ...

Page 17: ...na desviación en la precisión del producto contacte a las instalaciones de servicio MILWAUKEE El no hacerlo puede provocar que se rechace una reclamación de la garantía Influencias sobre la precisión Los gradientes de la temperatura ambiente pueden afectar la precisión láser Para obtener resultados precisos y repetibles debe realizarse el siguiente procedimiento con el láser elevado del piso y col...

Page 18: ...3 hacia la pared opuesta y gire el láser 180 Permita que el láser se au tonivele 4 Ajuste la altura de la herramienta con un tripié o con calzas de ser necesario para que el centro de la línea horizontal se proyecte exactamente contra el punto II previamente marcado en la pared B Asegúrese de que el láser se autonivele después de la alineación 5 Marque el centro de la línea horizontal en la pared ...

Page 19: ...bién marque el centro del punto de plomada en el piso punto II 5m 16 5 4 Gire la herramienta 180 Alinee el punto central del rayo láser directamente en el punto II del piso 5 Marque el centro del punto de plomada superior en la línea de referencia del techo punto III d 6 La distancia entre los puntos I y III en el techo es la desviación d de la herramienta Esta distan cia no debe superar 3 mm 1 8 ...

Page 20: ...taciones anteriores Si durante el uso normal el LED o Bulbo de LED falla la parte será reemplazada sin cargo No se requiere el registro de la garantía para obtener la garantía cor respondiente a un producto de herramienta eléctrica de MILWAUKEE La fecha de manufactura del producto se utilizará para determinar el periodo de garantía si no se proporciona comprobante de compra al solicitar el servici...