background image

4

5

The grounding prong in the plug is con-
nected through the green wire inside the
cord to the grounding system in the tool.
The green wire in the cord must be the
only wire connected to the tool's ground-
ing system and must never be attached to
an electrically “live” terminal.

Your tool must be plugged into an appro-
priate outlet, properly installed and
grounded in accordance with all codes and
ordinances. The plug and outlet should look
like those in Figure A.

Double Insulated Tools:
Tools with Two Prong Plugs

Tools marked “Double Insulated” do not re-
quire grounding. They have a special
double insulation system which satisfies
OSHA requirements and complies with the
applicable standards of Underwriters Labo-
ratories, Inc., the Canadian Standard As-
sociation and the National Electrical Code.
Double Insulated tools may be used in ei-
ther of the 120 volt outlets shown in
Figures B and C.

Grounded Tools:
Tools with Three Prong Plugs

Tools marked “Grounding Required” have
a three wire cord and three prong ground-
ing plug. The plug must be connected to a
properly grounded outlet (See Figure A). If
the tool should electrically malfunction or
break down, grounding provides a low re-
sistance path to carry electricity away from
the user, reducing the risk of electric shock.

Fig. B

Fig. C

Fig. A

Improperly connecting the
grounding wire can result in the
risk of electric shock. Check
with a qualified electrician if you
are in doubt as to whether the
outlet is properly grounded. Do
not modify the plug provided
with the tool. Never remove the
grounding prong from the plug.
Do not use the tool if the cord or
plug is damaged. If damaged,
have it repaired by a 

MILWAUKEE

service facility before use. If the
plug will not fit the outlet, have a
proper outlet installed by a quali-
fied electrician.

GROUNDING

WARNING!

1.

Hold tool by insulated gripping surfaces when performing an operation where
the cutting tool may contact hidden wiring or its own cord. 
Contact with a “live”
wire will make exposed metal parts of tool “live” and shock the operator.

2.

Maintain labels and nameplates. These carry important information. If
unreadable or missing, contact a

 MILWAUKEE service facility for a free replacement.

3.

WARNING! Some dust created by power sanding, sawing, grinding, drilling, and other
construction activities contains chemicals known to cause cancer, birth defects or
other reproductive harm. Some examples of these chemicals are:

lead from lead-based paint

crystalline silica from bricks and cement and other masonry products, and

arsenic and chromium from chemically-treated lumber.

Your risk from these exposures varies, depending on how often you do this type of
work. To reduce your exposure to these chemicals: work in a well ventilated area, and
work with approved safety equipment, such as those dust masks that are specifically
designed to filter out microscopic particles.

SPECIFIC SAFETY RULES

Amperes

Double Insulated

Symbology

Canadian Standards
Association

Underwriters
Laboratories, Inc.

Volts Alternating/
Direct Current

Speed Feet per Minute

Speed

feet/min.

1400

Volts

AC/DC

120

Cat.

No.

5936

Specifications

A m p s

10

Belt Size

4" x 24"

SFPM

Summary of Contents for 5936

Page 1: ...L AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DEBE LEER Y ENTENDER EL MANUAL DEL OPERADOR...

Page 2: ...e insula tion eliminates the need for the three wire grounded power cord and grounded power supply system 6 Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators T...

Page 3: ...rly grounded Do not modify the plug provided with the tool Never remove the grounding prong from the plug Do not use the tool if the cord or plug is damaged If damaged have it repaired by a MILWAUKEE...

Page 4: ...on tains at least the minimum wire size re quired If you are using one extension cord for more than one tool add the nameplate amperes and use the sum to determine the required minimum wire size Guide...

Page 5: ...rigger for con tinuous sanding 1 To lock the trigger hold in the lock but ton while squeezing the trigger Re lease the trigger and it will lock in place 2 To release the lock button squeeze and releas...

Page 6: ...these include gasoline turpentine lacquer thinner paint thinner chlorinated cleaning solvents ammonia and household deter gents containing ammonia Never use flam mable or combustible solvents around t...

Page 7: ...dommag augmente le risque de choc lectrique 9 Lorsque vous utilisez un outil lectrique l ext rieur employez un prolongateur pour l ext rieur marqu W A ou W Ces cor dons sont faits pour tre utilis s l...

Page 8: ...et de mieux r agir une situation inattendue 15 Utilisez des accessoires de s curit Portez toujours des lu nettes ou une visi re Selon les con ditions portez aussi un masque antipoussi re des bottes de...

Page 9: ...0 de l intensit moyenne de courant Outils mis la terre Outils pourvus d une fiche de cordon trois dents Les outils marqu s Mise la terre requise sont pourvus d un cordon trois fils dont la fiche a tro...

Page 10: ...Gros pour un pon age rapide Moyen pour le lissage Fin pour le finissage Pon age g n ral Pon age de la fibre de verre du plastique de la pierre du marbre du verre de l aluminium de la fonte du cuivre...

Page 11: ...sion D gagez le bouton de verrouillage Laissez la ponceuse s arr ter compl tement avant de la poser Une courroie en mouvement peut d placer la ponceuse m me si le moteur est arr t Voyez la section sur...

Page 12: ...r tez imm diatement l outil et faites le v rifier avant de vous en servir de nouveau N utilisez pas un outil d fectueux Fixez y une tiquette marqu e HORS D USAGE jusqu ce qu il soit r par voir R parat...

Page 13: ...rvicio o mantenimiento realizado por personal no calificado puede aumentar el riesgo de lesiones 25 Cuando realice el servicio de mantenimiento utilice solamente repuestos id nticos Siga las instrucci...

Page 14: ...tienen un sistema aislante que satisface los est ndares de OSHA y llena los est ndares aplicables de UL Underwriters Laborato ries de la Asociaci n Canadiense de Est ndares CSA y el C digo Nacional de...

Page 15: ...lacas y use la suma para determinar el tama o m nimo del cable de extensi n LEAYGUARDETODASLASINSTRUCCIONESPARA FUTURASREFERANCIAS EXTENSIONESELECTRICAS Gu as para el uso de cables de extensi n Si est...

Page 16: ...0 100 120 220 120 220 120 220 Fig 1 Fig 2 Lijado 1 Aseg rese que el cord n no entre en contacto con la correa Sujete las empu aduras firmemente 2 Arranque la lijadora fuera de la superficie de trabajo...

Page 17: ...en direcci n de la fibra para remover ralladuras producidas por las correas de grano m s grueso Siempre finalice su trabajo lijando en direcci n de la fibra Fig 4 Tenga cuidado de no pasarse del extr...

Page 18: ...ramienta de inmediato y corrija el problema antes de volver a usarla No utilice una herramienta da ada Col quele una etiqueta que diga NO DEBE USARSE hasta que sea reparada vea Reparaciones Bajo condi...

Page 19: ...oln no 13 Colonia Los Reyes Zona Industrial Tlalnepantla Edo M xico C P 54073 Tels 5565 1414 5565 4720 Fax 5565 0925 MEXICO Milwaukee Electric Tool Canada Ltd 755 Progress Avenue Scarborough Ontario M...

Reviews: