5
1
2
3
DC
5 V
0,1 - 2,1 A
Red breathing
Charging, 0-49% charged
Yellow breathing
Charging, 50-99% charged
Green solid
100% charged
Red/Green
fl
ashing
No battery, damaged battery, faulty battery, over temperatur
Red breathing
Charging during use
Green
fl
ashing
No battery inserted during use
ENGLISH
LOW BATTERY INDICATION
When the voltage is low, the laser switch to power safe mode.
The laser will blink in self leveling mode
4 sec.
1 sec.
The laser will blink in manual mode
8 sec.
1 sec.
From now on it is still possible to continue the work.
When the voltage is too low, the laser and the LED will
fl
ash 3 times and it automatically shuts
down.
After switch on or switch o
ff
the laser the fuel gauge will display the battery life for 3 seconds
FUEL GAUGE
CHARGE
It is possible to work with the laser during charge.
Green solid
100% - 50% remaining
Yellow solid
49% - 11% remaining
Red solid
10% - 3% remaining
Red
fl
ashing
3% - 0% remaining