background image

10

11

CAUTION

 Looking into the 

laser beam may be hazardous to the 
eyes. Do not stare into beam. Do not 
look into the laser beam. Make sure 
the laser is aimed above or below 
eye level (particularly with fixed 
installations, in machines, etc.).

WARNING

 The MILWAUKEE 

Laser Distance Meter conforms to the 
most stringent requirements of the 
relevant standards and regulations. 
Yet the possibility of the product 
causing interference in other equip-
ment cannot be fully excluded. 

Laser classifi cation

The 

MILWAUKEE

 Laser Distance Meter 

produces a visible laser beam which 
emerges from the front of the meter. 
The product is a Class 2 Laser Product 
in accordance with IEC60825-1 : 2007 
"Radiation safety of laser products"
Class 2 Laser Products:
Do not stare into the beam or direct it 
unnecessarily at other persons. Eye pro-
tection is normally afforded by aversion 
responses including the blink refl ex.

WARNING

 Looking directly 

into the laser beam with optical aids 
(e.g. binoculars, telescopes) can be 
hazardous.

Code Cause Correction

204 Calculation error

Repeat procedure

252 Temperature too high

Let meter cool down

253 Temperature too low

Warm up meter

255 Received signal too weak, time 

for a measurement too long

Create solid color target plate

256 Received signal too strong

Create solid color target plate (gray)

257 Faulty measurement, too much 

background light

Create solid color target plate (brown)

258 Outside the range of 

measurement

Select measurement distance within the range of 
measurement

Error Hardware error 

Should this message remain active after switching 
the meter off and on several times, please contact a 

MILWAUKEE

 service facility

Federal Communications 
Commission

WARNING: Changes or modifi cations to this 
unit not expressly approved by the party re-
sponsible for compliance could void the user’s 
authority to operate the equipment.
This equipment has been tested and found 
to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reason-
able protection against harmful interference in 
a residential installation. This equipment gen-
erates, uses and can radiate radio frequency 
energy and, if not installed and used in accor-
dance with the instructions, may cause harmful 
interference to radio communications.

Appendix
Display notices - 

All display notices are either displayed with 

 or "Error". The 

following errors can be corrected.

Electromagnetic Compatibility (EMC)

The term "electromagnetic compatibility" 
is taken to mean the capability of the 
product to function smoothly in an envi-
ronment where electromagnetic radiation 
and electrostatic discharges are present, 
and without causing electromagnetic 
interference to other equipment.

MAINTENANCE

WARNING 

To reduce the 

risk of personal injury and damage, 
never immerse your tool in liquid or 
allow a liquid to fl ow inside it.

WARNING 

To reduce the risk 

of injury, always remove the batter-
ies from the tool before performing 
any maintenance. Never disassem-
ble the tool. Contact a MILWAUKEE
 
service facility for ALL repairs.

Cleaning

Clean dust and debris from tool. Keep 
tool handles clean, dry and free of oil or 
grease. Use only mild soap and a damp 
cloth to clean the tool since certain clean-
ing agents and solvents are harmful to 
plastics and other insulated parts. Some 
of these include gasoline, turpentine, 
lacquer thinner, paint thinner, chlorinated 
cleaning solvents, ammonia and house-
hold detergents containing ammonia. 
Never use fl ammable or combustible 
solvents around tools.

Repairs

For repairs, return the tool to the nearest 
service center listed on the back cover 
of this operator's manual.

Maintaining tool 

Keep your tool in good repair by adopting 
a regular maintenance program. After six 
months to one year, depending on use, 
return the tool to 

a MILWAUKEE

 service 

facility for service.
If the tool does not start or operate at full 
power with fully charged batteries, clean 
the contacts on the battery door. If the 
tool still does not work properly, return 
the tool to a 

MILWAUKEE

 service facility 

for repairs.

Cleaning the laser windows

Clean the laser windows with a soft, 
moist cloth to keep them clean and clear. 
Remove batteries before cleaning.

However, there is no guarantee that interfer-
ence will not occur in a particular installation. 
If this equipment does cause harmful interfer-
ence to radio or television reception, which 
can be determined by turning the equipment 
off and on, the user is encouraged to try to 
correct the interference by one or more of the 
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equip-

ment and receiver.

• Connect the equipment into an outlet on a 

circuit different from that to which the receiver 
is connected.

• Consult the dealer or an experienced radio/

TV technician for help.

Summary of Contents for 2280-20

Page 1: ...MUST READ AND UNDERSTAND OPERATOR S MANUAL AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DE...

Page 2: ...in a cool dry place Do not store where temperatures may exceed 158 F 70 C such as in direct sunlight a vehicle or metal building during the summer Stay alert watch what you are do ing and use common s...

Page 3: ...2 3 4 5 6 6 OPERATION Timer Press the 1 button to set the timer to 5 seconds Use the or buttons to change the time lapse On the first measurement the count 2 down begins immediately For addi tional me...

Page 4: ...is displayed in Intermediate Line 1 the previous value is displayed in Intermediate Line 2 Area Press the 1 button once to deter mine area Press the 2 button to take the first measurement e g length P...

Page 5: ...sure a length using three points The distance to be measured flashes 2 on the display Press the button to take the measurement To determine the maximum distance press and hold the button A con tinuous...

Page 6: ...Display notices All display notices are either displayed with or Error The following errors can be corrected Electromagnetic Compatibility EMC The term electromagnetic compatibility is taken to mean...

Page 7: ...g contact your local distributor or a service center WARNING Always remove batteries before changing or remov ing accessories Only use accesso ries specifically recommended for this tool Others may be...

Page 8: ...re le polystyr ne et les autres surfaces semi perm ables semblables peuvent causer des er reurs de mesure Le fait de viser des surfaces luisantes peut faire d vier le faisceau laser et att nuer la pr...

Page 9: ...er les boutons ou pour modifier l intervalle 2 Au moment de la premi re prise mesure le d compte commence im m diatement Pour prendre d autres mesures appuyer sur le bouton afin de commencer le d comp...

Page 10: ...nir enfonc L appareil commence mettre un signal sonore et prendre des mesures de fa on continue 2 Appuyer de nouveau sur le bouton pour cesser de prendre des mesures de fa on continue 3 La plus r cent...

Page 11: ...ligne interm diaire 1 6 La valeur du volume s affiche sur la ligne Cibles principales La troisi me mesure s affiche sur la ligne interm diaire 1 et la deuxi me mesure s affiche sur la ligne interm dia...

Page 12: ...TISSEMENTL appareil de mesure de la distance au laser est conforme aux exigences les plus strictes des normes et des r glements applicables l heure actuelle on ne peut exclure compl tement la possibil...

Page 13: ...y compris l outil les blocs piles au lithium ion et le chargeur mais non les piles alcalines sont garantis l acheteur d origine tre exempt de vice du mat riau et de fabrication Sous r serve de certain...

Page 14: ...as bater as seg n los diagra mas de polaridad Deseche de inmediato las bater as usadas en forma correcta No incinere ni desarme las bater as En condiciones abusivas puede salir l quido expulsado de la...

Page 15: ...a 104 F ESPECIFICACIONES En condiciones dif ciles con luz solar intensa con una superficie objetivo poco reflectante o con temperaturas altas la desviaci n sobre distancias de aproxima damente 10 m 32...

Page 16: ...a vez para medir desde el borde delantero A Despu s de tomar una medici n la referencia vuelve autom ticamente a la configuraci n predeterminada B referencia posterior OPERATION Temporizador 1 Presion...

Page 17: ...2nd 1st Se obtienen mejores resultados cuan do se gira el tel metro sobre un punto fijo p ej el soporte de extremo est totalmente extendido y colocado contra una pared Use la funci n m nimo m ximo par...

Page 18: ...lanteo p ej 162 5 cm 64 para una distancia de replanteo de 406 4 mm 16 se muestra en la l nea intermedia 1 La distancia al siguiente punto de replanteo se mues tra en la l nea de objetivos principales...

Page 19: ...se produzca interferencia en una instalaci n concreta Si este equipo en efecto genera interferencia perjudicial para la recepci n de radio o televisi n que se puede determinar apagando y encendiendo...

Page 20: ...cinco 5 a os despu s de la fecha de compra Env e la herramienta de pruebas y mediciones y una copia del comprobante de la compra al centro de servicio m s cercano de f brica de MILWAUKEE Electric Too...

Page 21: ...te at www milwaukeetool com For service information use the Service Center Search icon found in the Parts Service section Additionally wehaveanationwidenetworkof authorizedDistributorsready to assist...

Reviews: