Indirect measurement – 
the third leg of a triangle

Indirect measurement – 
measuring a length 
with three points

 

90°

2

nd

1

st

Press the 

1. 

 button three times to 

use the Pythagorean method to deter-
mine the third leg of a triangle 

.

The distance to be measured fl ashes 

2. 

on the display. Press the 

 button to 

take the fi rst measurement. 
To determine the maximum distance, 
press and hold the 

 button. A con-

tinuous measurement is taken, saving 
the maximum distance. Press the 

 

button again to stop. 
The second distance to be measured 

3. 

fl ashes on the display. Press the 

 

button to take the second measure-
ment.
To determine the minimum distance, 
press and hold the 

 button. A con-

tinuous measurement is taken, saving 
the minimum distance. Press the 

 

button again to stop.
The resulting third leg of the triangle 

4. 

is displayed in the Main Targets 
line. The second measurement is 
displayed in Intermediate Line 1 and 
the fi rst measurement is displayed in 
Intermediate Line 2. 

90°

3

rd

2

nd

1

st

Stake out

Use this function to stake out equal 
distances, such as locating studs on 
16" centers. 

16"

16"

16"

1

st

2

nd

3

rd

Press the 

1. 

 button fi ve times.

The the stake out distance and the 

2. 

 symbol are displayed. To adjust 

the stake out distance, use the 

 

and 

 buttons.

Point the meter at the fi rst stake. 

3. 

Press the 

4. 

 button to start the con-

tinuous measurement.

The next approximate multiple of the 

5. 

staking distance (e.g., 64" for a stak-
ing distance of 16") is displayed in 
Intermediate Line 1. The distance to 
the next stake point is displayed in the 
Main Targets line (e.g., 1-3/4"). 

Begin sliding the meter away from the 

6. 

fi rst stake. As the next stake out point 
is neared, the meter starts to beep. 

When the next stake out point is 

7. 

reached, the beep sound changes 
and the top line of the display starts 
to fl ash. 

Take note of the meter Reference; the 
stake out point is the set reference - 
front, rear, or end bracket.

Press the 

1. 

 button four times to use 

the Pythagorean method to measure a 
length using three points 

.

The distance to be measured fl ashes 

2. 

on the display. Press the 

 button to 

take the measurement. 

  To determine the maximum distance, 

press and hold the 

 button. A con-

tinuous measurement is taken, saving 
the maximum distance. Press the 

 

button again to stop. 
The second distance to be measured 

3. 

fl ashes on the display. Press the 

 

button to take the measurement.
To determine the minimum distance, 
press and hold the 

 button. A con-

tinuous measurement is taken, saving 
the minimum distance. Press the 

 

button again to stop.
The third distance to be measured 

4. 

fl ashes on the display. Press the 

 

button to take the measurement.

  To determine the maximum distance, 

press and hold the 

 button. A con-

tinuous measurement is taken, saving 
the maximum distance. Press the 

 

button again to stop.
The resulting length is displayed in the 

5. 

Main Targets line. The third measure-
ment is displayed in Intermediate Line 
2 and the second measurement is 
displayed in Intermediate Line 2. 

Volume 

 

Press the 

1. 

 button twice to deter-

mine volume 

 .

Press the 

2. 

 button to take the fi rst 

measurement (e.g. length).
Press the 

3. 

 button again to take the 

second measurement (e.g. width). 
The resulting area is displayed in the 

4. 

Main Targets line and the individual 
measurements are displayed in In-
termediate Line 1 and Intermediate 
Line 2.
Press the 

5. 

 button again to take 

the third measurement (e.g. height). 
The value is displayed in Intermedi-
ate Line 1.
The resulting volume is displayed in 

6. 

the Main Targets line. The third mea-
surement is displayed in Intermediate 
Line 1 and the second measurement 
is displayed in Intermediate Line 2.

Indirect measurement

The meter can measure distances us-
ing the Pythagorean method. Use this 
function to measure distances in areas 
diffi cult to access. 

• 

All target points must be vertical or 
horizontal on the surface of the wall.

• 

The best results are achieved when the 
meter is rotated around a fi xed  point 
(e.g. the end bracket is fully extended 
and placed against a wall).

• 

Use the minimum/maximum function 
to determine the largest distances 
(maximum height) and smallest dis-
tance (right-angle) to be used in the 
calculation.

Summary of Contents for 2280-20

Page 1: ...MUST READ AND UNDERSTAND OPERATOR S MANUAL AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DE...

Page 2: ...in a cool dry place Do not store where temperatures may exceed 158 F 70 C such as in direct sunlight a vehicle or metal building during the summer Stay alert watch what you are do ing and use common s...

Page 3: ...2 3 4 5 6 6 OPERATION Timer Press the 1 button to set the timer to 5 seconds Use the or buttons to change the time lapse On the first measurement the count 2 down begins immediately For addi tional me...

Page 4: ...is displayed in Intermediate Line 1 the previous value is displayed in Intermediate Line 2 Area Press the 1 button once to deter mine area Press the 2 button to take the first measurement e g length P...

Page 5: ...sure a length using three points The distance to be measured flashes 2 on the display Press the button to take the measurement To determine the maximum distance press and hold the button A con tinuous...

Page 6: ...Display notices All display notices are either displayed with or Error The following errors can be corrected Electromagnetic Compatibility EMC The term electromagnetic compatibility is taken to mean...

Page 7: ...g contact your local distributor or a service center WARNING Always remove batteries before changing or remov ing accessories Only use accesso ries specifically recommended for this tool Others may be...

Page 8: ...re le polystyr ne et les autres surfaces semi perm ables semblables peuvent causer des er reurs de mesure Le fait de viser des surfaces luisantes peut faire d vier le faisceau laser et att nuer la pr...

Page 9: ...er les boutons ou pour modifier l intervalle 2 Au moment de la premi re prise mesure le d compte commence im m diatement Pour prendre d autres mesures appuyer sur le bouton afin de commencer le d comp...

Page 10: ...nir enfonc L appareil commence mettre un signal sonore et prendre des mesures de fa on continue 2 Appuyer de nouveau sur le bouton pour cesser de prendre des mesures de fa on continue 3 La plus r cent...

Page 11: ...ligne interm diaire 1 6 La valeur du volume s affiche sur la ligne Cibles principales La troisi me mesure s affiche sur la ligne interm diaire 1 et la deuxi me mesure s affiche sur la ligne interm dia...

Page 12: ...TISSEMENTL appareil de mesure de la distance au laser est conforme aux exigences les plus strictes des normes et des r glements applicables l heure actuelle on ne peut exclure compl tement la possibil...

Page 13: ...y compris l outil les blocs piles au lithium ion et le chargeur mais non les piles alcalines sont garantis l acheteur d origine tre exempt de vice du mat riau et de fabrication Sous r serve de certain...

Page 14: ...as bater as seg n los diagra mas de polaridad Deseche de inmediato las bater as usadas en forma correcta No incinere ni desarme las bater as En condiciones abusivas puede salir l quido expulsado de la...

Page 15: ...a 104 F ESPECIFICACIONES En condiciones dif ciles con luz solar intensa con una superficie objetivo poco reflectante o con temperaturas altas la desviaci n sobre distancias de aproxima damente 10 m 32...

Page 16: ...a vez para medir desde el borde delantero A Despu s de tomar una medici n la referencia vuelve autom ticamente a la configuraci n predeterminada B referencia posterior OPERATION Temporizador 1 Presion...

Page 17: ...2nd 1st Se obtienen mejores resultados cuan do se gira el tel metro sobre un punto fijo p ej el soporte de extremo est totalmente extendido y colocado contra una pared Use la funci n m nimo m ximo par...

Page 18: ...lanteo p ej 162 5 cm 64 para una distancia de replanteo de 406 4 mm 16 se muestra en la l nea intermedia 1 La distancia al siguiente punto de replanteo se mues tra en la l nea de objetivos principales...

Page 19: ...se produzca interferencia en una instalaci n concreta Si este equipo en efecto genera interferencia perjudicial para la recepci n de radio o televisi n que se puede determinar apagando y encendiendo...

Page 20: ...cinco 5 a os despu s de la fecha de compra Env e la herramienta de pruebas y mediciones y una copia del comprobante de la compra al centro de servicio m s cercano de f brica de MILWAUKEE Electric Too...

Page 21: ...te at www milwaukeetool com For service information use the Service Center Search icon found in the Parts Service section Additionally wehaveanationwidenetworkof authorizedDistributorsready to assist...

Reviews: