Pellerin Milnor Corporation
Figure 2. Detailed views
Legend
A.
Top connection between the shell front and the shell side sheet
B.
Bottom connection between the shell front and the shell side sheet
C.
Connection between the shell rear and the bearing housing
D.
Connection between the Pull-up plate and the Hub (outer bolts)
E.
Connection between the Pull-up plate and the Shaft (inner bolts)
M.
Use thread lock compound Locktite 242. Tighten to 1475 FT. LBS.
N.
Use thread lock compound Locktite 242. Tighten items 14 and 15 to 413 FT. LBS. (4 instances).
P.
Apply silicone to the hub side of the gasket.
Q.
0.25 inches [6.3mm].
R.
Use thread lock compound Locktite 242. Tighten items 16 and 17 to 36 IN. LBS. (18 instances).
S.
Use thread lock compound Locktite 242. Tighten items 20 and 15 to 413 FT. LBS. (4 instances).
T.
Apply oil to the o-rings before you assemble.
Cylinder and Bearing Installation
2 of 3
4840F, MWF100, MWF125
50
Summary of Contents for MWF125J7
Page 2: ......
Page 8: ......
Page 9: ...Installation 1 5 ...
Page 39: ...Service and Maintenance 2 35 ...
Page 51: ...2 Drive Assemblies 2 1 47 ...
Page 57: ...Pellerin Milnor Corporation Bearing Assembly 4840F MWF100 MWF125 2 of 6 53 ...
Page 71: ...2 Suspension 2 2 67 ...
Page 74: ......
Page 75: ...2 Door Assemblies 2 3 71 ...
Page 83: ...2 Water and Steam Assemblies 2 4 79 ...
Page 92: ......
Page 93: ...2 Chemical Supply Assemblies 2 5 89 ...
Page 98: ......
Page 99: ...2 Pneumatic Assemblies 2 6 95 ...
Page 103: ...2 Control and Sensing Assemblies 2 7 99 ...
Page 107: ...Reference 3 103 ...
Page 108: ......
Page 109: ...3 Dimensional Drawings 3 1 105 ...
Page 110: ......
Page 111: ...107 ...
Page 112: ...108 ...