OM-363 Page 14
3-9. Remote 14 Receptacle Information
Ref. 803 588-B
A
J
B
K
I
C L N
H
D M
G
E
F
!
Turn off power before
connecting to receptacle.
Socket*
Socket Information
24 VOLTS DC
OUTPUT
CONTACTOR
A
Contactor control 24 volts dc.
B
Contact closure to A completes 24 volts dc
contactor control circuit and enables output.
REMOTE
OUTPUT
CONTROL
A
C
Output to remote control; 0 to +10 volts dc output
to remote control.
D
Remote control/feedback circuit common.
E
0 to +10 volts dc input command signal from
remote control.
A/V
AMPERAGE
VOLTAGE
F
Current feedback; +1 volt dc per 100 amperes.
H
Voltage feedback; +1 volt dc per 10 volts output.
GND
K
Chassis common.
*The remaining sockets are not used.
3-10. Shielding Gas Connections And 115 Volts AC Duplex Receptacle
Ref. 803 588-B / Ref. 803 585-B / Ref. 157 858
!
Turn Off power before con-
necting to receptacle.
1
Gas Valve In Connection
Located on rear of unit.
2
Gas Valve Out Connection
Connections have 5/8-18 right-
hand threads.
3
Cylinder Valve
Open valve slightly so gas flow
blows dirt from valve. Close valve.
4
Regulator/Flow Gauge
Connect regulator/flow gauge to
gas cylinder.
Connect customer supplied gas
hose between regulator/flow gauge
and gas in fitting.
5
Flow Adjust
Typical flow rate is 20 cfh (cubic feet
per hour).
6
115 V 15 Amp AC Receptacle
Receptacle is protected from over-
load by circuit breaker CB1 (see
Section 5-3).
5
6
4
2
5/8, 3/4, 1-1/8 in
Tools Needed:
3
Front View
1
Rear View
Summary of Contents for Syncrowave 250 DX
Page 6: ......
Page 35: ...ENGLISH OM 363 Page 29 Notes...
Page 43: ...ENGLISH OM 363 Page 37 CE Nameplate E 2 1 2 3 4...
Page 47: ...ENGLISH OM 363 Page 41 CE Nameplate 00 4 SEL 1 4 2...
Page 61: ...ENGLISH OM 363 Page 55 231 395 B Figure 7 2 Circuit Diagram For 350 LX Models...
Page 62: ...OM 363 Page 56 225 650 A Figure 7 3 Circuit Diagram For Optional Cooler...
Page 69: ...ENGLISH OM 363 Page 63 Notes...
Page 80: ...Notes...