OM-1500-16 Page 17
4-10. Connecting Shielding Gas
805 128-A
NOTICE − This feeder has a shield-
ing gas filter that requires special
attention when cleaning. See Sec-
tion 6-3 for proper cleaning instruc-
tions.
1
Gas Hose With 5/8-18
Right-hand Thread Fittings
(Customer Supplied)
2
Shielding Gas Cylinder
.
Shielding gas pressure not to
exceed 100 psi (689 kPa).
3
Valve
4
Flowmeter
5
14-Pin Plug
Close valve on cylinder when fin-
ished welding.
1
Rear View
2
3
4
5
4-11. Connecting Weld Cable
Ref. 132 808-F / Ref. 805 130-B
1
User-Suppled Weld Cable
Follow wire manufacturer’s recom-
mendations for weld cable polarity.
2
Male Connector
3
User-Suppled Female
Connector
Connect male and female connec-
tors.
2
1
3
From Wire Feeder
Internal Side View