OM-1500-16 Page 22
5-3.
Setting Digital Meter Board PC4 DIP Switches
803 141/ Ref. 803 124
1
Front Meter Panel
2
S1 DIP Switch
3
S2 DIP Switch
If the DIP switches are set to a Meter
Hold (ON) position, the meter value
will hold 5 seconds after gun is trig-
gered. The meter value will continue
to hold for 8 seconds after trigger is
released or until gun is re-triggered.
.
When using power sources
without 14 pin voltage/current
feedback − optional remote
voltage/current kit 195 194 is
required.
Indicates this DIP switch setting has
no effect on this function.
14 Pin
Voltage
Feedback
1
3
2
Wire Feed Speed Display
Voltage
Sense Lead
(Optional)
S1
S2
Meters Per Minute
Inches Per Minute
Meter Hold
S1
(OFF)
S2
Amps Display
Current Sensor
(Optional)
14 Pin
Current
Feedback
S2
S1
(ON)
14 Pin
Voltage
Feedback
Voltage
Sense Lead
(Optional)
S2
S2
S2
S1
.
Meter DIP switches are factory set to
display wirefeed speed in inches per
minute, voltage and amperage thru 14
pin feedback. Meter hold feature is
factory set to off position.