A complete Parts List is available on-line at www.MillerWelds.com
OM265809 Page 28
6-2. Using Auto-Set
1
Process Select Control
Turn control to select process, material,
and type of shielding gas.
2
Wire Speed/Wire Diameter Control
To turn Auto-Set on, turn the Wire Speed/
Wire Diameter control knob to the desired
wire diameter setting.
3
Auto-Set LED
The Auto-Set light illuminates indicating
Auto-Set is on.
.
A blinking Auto-Set LED indicates pa-
rameter is not recommended.
4
Voltage/Material Thickness Control
Adjust the Voltage/Material Thickness
control knob to the desired steel material
thickness to weld.
.
There is no adjustment within the
material thickness band.
265381A
4
2
3
1
6-3. Jog Mode
If gun trigger is held for longer than 3 seconds without initiating a weld arc, unit will enter Jog mode and disable weld output.
S
Jog mode is used to quickly feed wire through the wire drive assembly and MIG gun.
S
While in Jog mode, wire feed speed is adjustable using the Wire Speed/Wire Diameter control knob.
S
To exit Jog mode, release gun trigger.