A complete Parts List is available on-line at www.MillerWelds.com
OM265809 Page 10
SECTION 4
−
SPECIFICATIONS
4-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on back. Use rating label to determine input power requirements and/or rated output.
For future reference, write serial number in space provided on back cover of this manual.
4-2. Unit Specifications
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-3, 5-4 and 5-5 for information on
connecting input power.
Input
Voltage
Rated
Welding
Output
Amperage Range
Maximum
Open Circuit
Voltage DC
(U
0
*)
Amperes Input at Rated
Load Output,
50/60HZ, Single
−
Phase
KVA KW
Weight
w/ Gun
Overall
Dimensions
120 VAC
115 A @ 19.8
Volts DC, 20%
Duty Cycle
30
−
130
54
24.3
2.9
2.9
42 lb.
(19 kg)
Length: 20.5 in.
(521 mm)
Width: 11.25 in.
(286 mm)
Height: 12.5 in.
(318 mm)
Wire Type
and Dia
Solid/Stainless
Flux Cored
Wire Feed Speed Range
.023
−
.035 in.
(0.6
−
0.9 mm)
.030
−
.035 in.
(0.8
−
0.9 mm)
60
−
600 IPM
(1.5
−
15.24 m/min)
240 VAC
150 A @21.5
Volts DC,
40% Duty Cycle
30
−
230
54
16.6
4.0
4.0
Wire Type
and Dia
Solid/Stainless
Flux Cored
Wire Feed Speed Range
.023
−
.035 in.
(0.6
−
0.9 mm)
.030
−
.045 in.
(0.8
−
1.2 mm)
60
−
600 IPM
(1.5
−
15.24 m/min)
*See unit rating label and Section 3-2.
4-3. Environmental Specifications
A. IP Rating
IP Rating
IP21
This equipment is designed for indoor use and is not intended to be used or stored outside.
IP21 2014
−