A complete Parts List is available on-line at www.MillerWelds.com
OM265809 Page 24
5-14. Installing Gas Supply
Obtain gas cylinder and chain to
running gear, wall, or other
stationary support so cylinder
cannot fall and break off valve.
1
Cap
2
Cylinder Valve
Remove cap, stand to side of valve,
and open valve slightly. Gas flow
blows dust and dirt from valve.
Close valve.
3
Cylinder
4
Regulator/Flowmeter
Install so face is vertical.
5
Regulator/Flowmeter Gas
Hose Connection
6
Welding Power Source Gas
Hose Connection
Connect supplied gas hose
between regulator/flowmeter gas
hose connection, and fitting on rear
of welding power source.
7
Flow Adjust
Flow rate should be set when gas is
flowing through welding power
source and welding gun. Open
feedhead pressure assembly so
that wire will not feed. Press gun
trigger to start gas flow.
Typical flow rate is 20 to 25 cfh
(cubic feet per hour). Check wire
manufacturer’s recommended
flow rate.
8
CO
2
Adapter (Customer
Supplied)
9
O-Ring (Customer Supplied)
Install adapter with O-ring between
regulator/flowmeter and CO
2
cylinder.
After flow is set, close feedhead
pressure assembly.
270208A / Ref. 247832A / Ref. 267807A / Ref. 267805A
5/8, 1-1/8 in.
1
2
3
Argon Gas Or
Mixed Gas
4
5
7
.
DO NOT use Argon/Mixed gas regulator/flowmeter
with CO
2
shielding gas. See Parts List for optional
CO
2
gas regulator/flowmeter and hose.
Feedhead Pressure Assembly Open
Feedhead Pressure Assembly Closed
6
Tools Needed:
CO
2
Gas
8