OM-235 241 Page 16
5-3.
Memory Control
956.142.656
.
The first three alphanumeric digits of
the display indicate the desired action
being requested for the selected
memory position.
.
The fourth alphanumeric digit of the dis-
play shows the selected memory posi-
tion. If the fourth digit is −, than the re-
quested action is not valid for the selec-
ted memory position.
LOA − Loads the welding parameters previ-
ously stored by the operator from the spe-
cified memory position.
STO − Stores welding parameters set by
the operator to an operator specified
memory position.
DEL − Permanently deletes stored welding
parameters from a specified memory posi-
tion.
.
All memory positions are empty when
machine leaves factory
.
Document all welding parameters for
each memory position.
.
Welding parameter data is stored until
intentionally deleted, or a recall of fact-
ory parameters is performed (see Sec-
tion 5-4).
1
Process Control
Use control to enter memory control and
confirm selected action.
2
Setup Control
Use control to exit memory control.
3
Decrease Control
Use control to scroll through the desired ac-
tions required for the selected memory pos-
itions, LOA, STO, and DEL.
4
Increase Control
Use control to scroll through memory posi-
tions 0−9.
5
Ammeter And Parameter Display
6
Power Switch
To create or change a welding paramet-
er memory position, proceed as follows:
Select desired process, Stick, TIG Lift, TIG
Lift Pulse, TIG HF, TIG HF Pulse.
Set or modify all desired parameters.
With power on, press and hold Process
control until LOA is displayed .
Press and hold Decrease control until STO
is displayed.
Press Increase control to select desired
memory position 0−9.
Press Process control until OK is dis-
played.
To Recall a welding parameter memory
position, proceed as follows:
Press and hold Process control until LOA is
displayed .
Press Increase control to select desired
memory position 0−9.
Press Process control until OK is dis-
played.
To delete welding parameters from a
memory position, proceed as follows:
Press and hold Process control until LOA is
displayed .
Press and hold Decrease control until DEL
is displayed.
Press Increase control to select desired
memory position 0−9.
Press and release Setup control to exit
memory control.
1
2
3
4
5
6