OM-235 241 Page 17
5-4.
Resetting Unit To Factory Default Settings
956.142.656
.
Document all welding
parameters for each
memory position.
.
This procedure will delete
all operator specified
parameters, and recall all
factory parameters..
1
Process Control
2
Increase Control
3
Ammeter And Parameter
Display
4
Power Switch
Turn unit off. Press and hold-
ing the Process and Increase
controls, turn unit on, wait for
CLR to display before releas-
ing controls.
1
2
3
4
5-5.
Selecting Remote Control
956.142.656
.
Document all welding
parameters for each
memory position.
1
Setup Control
2
Decrease Control
3
Increase Control
4
Ammeter And Parameter
Display
5
Power Switch
Turn unit on. Press and hold
Setup control until INT or EXT
is displayed. Press Increase
or Decrease controls to
change between INT and
EXT.
Press Setup control, and OK
will display.
INT − indicates weld se-
quence is initiated when elec-
trode makes contact with
workpiece. INT should be
used for Stick, TIG Lift, and
TIG Lift with pulse only
EXT − indicates weld se-
quence is initiated with some
external type of remote con-
trol.
1
2
5
4