OM-275857 Page 65
�
Complete Parts List is available at www.MillerWelds.com
11-3. Voltmeter/Ammeter Display Messages
�
All directions are in reference to the front of the unit. All circuitry referred to is located inside the unit.
Message Type
Display Message
Description
Release Trigger
[RELE] [ASE] /
[TRIG] [GER]
Remote 14 receptacle contactor control (Pins A-B) must be opened before
proceeding.
Un Short Output
[UN S] [HORT] /
[OUTP] [UT]
Short on weld output connections must be removed before proceeding. See
Section 11-4if display shows after weld output connections have been verified
as not having a short.
Over Temperature Error
[OVER] [TEMP]
Over temperature condition has occurred. Error will clear after temperatures
reach acceptable levels.
Latching Error
When one of the following errors occurs, the Standby LED flashes. To clear error, press Standby button or turn
off power. See Section 11-4 if error does not clear or happens frequently.
[CHEK] [INPT]
Check Input: High or low voltage has been sensed. Have a qualified person
check input voltage.
[WELD] [CABL]
Weld Cable: An error related to the weld cables has been sensed. Straighten
out or shorten weld cables. If Carbon arc gouging, adjust DIG setting to Car-
bon ARC. See Section 6-2 (Dynasty) or 7-2 (Maxstar).
[SEE] [O.M.]
See Owner’s Manual: See Section 11-4.
Not Valid
[NOT] [VALD]
Message is displayed when attempting an incompatible setup; i.e., pressing
AC Waveshape while in DC.
Lock Level
[LOCK] [LEV1]
Is displayed when attempting adjustments that are incompatible with the ac-
tive selected lock level.
Software Not Valid
[SOFT] [WARE] /
[NOT] [VALD]
A software compatibility error has been detected. A software update is re-
quired (see Section 5-17). See Section 11-4 if display shows after a software
update is performed.
[REMO] [TE]
Message is displayed when attempting an incompatible setup with remote
pendant connected to 14-pin receptacle. Front panel is disabled with excep-
tion of access to Tech Menu.
[ADV] [AUTO]
Message is displayed when attempting an incompatible setup with 28-pin Ad-
vanced Automation enabled.
Summary of Contents for Dynasty 400
Page 78: ...OM 275857 Page 68 275852 H Figure 12 2 Dynasty 400 Circuit Diagram Page 2 of 2...
Page 80: ...OM 275857 Page 70 Figure 12 4 Maxstar 400 Circuit Diagram Page 2 of 2...
Page 81: ...OM 275857 Page 71 275854 G Figure 12 5 Dynasty 800 Circuit Diagram Page 1 of 2...
Page 82: ...OM 275857 Page 72 275854 G Figure 12 6 Dynasty 800 Circuit Diagram Page 2 of 2...
Page 83: ...OM 275857 Page 73 Figure 12 7 Maxstar 800 Circuit Diagram Page 1 of 2...