![Miller Dynasty 400 Owner'S Manual Download Page 76](http://html1.mh-extra.com/html/miller/dynasty-400/dynasty-400_owners-manual_1796123076.webp)
OM-275857 Page 66
�
Complete Parts List is available at www.MillerWelds.com
11-4. Troubleshooting Table
Trouble
Remedy
No weld output; unit completely
inoperative.
Place line disconnect switch in On position (see Section 5-15).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 5-15).
Check for proper input power connections (see Section 5-15).
No weld output; meter display On.
If using remote control, be sure correct process is enabled to provide output control at Remote 14 re-
ceptacle (see Section 5-4 as applicable).
Input voltage outside acceptable range of variation (see Section 5-14).
Check, repair, or replace remote control.
Unit overheated. Allow unit to cool with fan On (see Section 4-7).
Erratic or improper weld output.
Use proper size and type of weld cable (see Section 5-3).
Clean and tighten all weld connections (see Section 11-1).
Fan not operating.
Check for and remove anything blocking fan movement.
Have Factory Authorized Service Agent check fan motor.
Wandering arc.
Use proper size tungsten (see Section 14).
Use properly prepared tungsten (see Section 14).
Reduce gas flow rate.
Tungsten electrode oxidizing and not
remaining bright after conclusion of
weld.
Shield weld zone from drafts.
Increase postflow time.
Check and tighten all gas fittings (see Section 11-1).
Water in torch. Refer to torch manual.
Blank display.
Verify Power to machine.
A software update may be required (see Section 5-17). Contact factory if display remains blank after
a software update is performed.
Error message [ERR] [LOG] is
displayed.
Contact a Factory Authorized Service Agent for an explanation of the error code.
Latching Errors (see Section 11-3).
Contact a Factory Authorized Service Agent if error does not clear or happens frequently.
Error message [SEE] [O.M.] is
displayed.
Contact a Factory Authorized Service Agent.
Tech Menu [SERL][NUM] is selected,
and serial number displayed does not
match serial number of machine (see
Section 9-1).
Contact a Factory Authorized Service Agent.
Error message [UN S] [HORT] /
[OUTP] [UT] is displayed.
Contact a Factory Authorized Service Agent if display shows after weld output connections have
been verified as not having a short.
Error message [SOFT] [WARE] [NOT]
[VALD] is displayed.
Contact a Factory Authorized Service Agent if display shows after a software update is performed.
Summary of Contents for Dynasty 400
Page 78: ...OM 275857 Page 68 275852 H Figure 12 2 Dynasty 400 Circuit Diagram Page 2 of 2...
Page 80: ...OM 275857 Page 70 Figure 12 4 Maxstar 400 Circuit Diagram Page 2 of 2...
Page 81: ...OM 275857 Page 71 275854 G Figure 12 5 Dynasty 800 Circuit Diagram Page 1 of 2...
Page 82: ...OM 275857 Page 72 275854 G Figure 12 6 Dynasty 800 Circuit Diagram Page 2 of 2...
Page 83: ...OM 275857 Page 73 Figure 12 7 Maxstar 800 Circuit Diagram Page 1 of 2...