OM-275857 Page 23
�
Complete Parts List is available at www.MillerWelds.com
5-4.
Remote 14 Receptacle Information
2-2.
Remote 14 Receptacle Information
804746-B / 218716-A
A
J
B
K
I
C
L
N
H
D
M
G
E
F
2-3.
Simple Automation Application (14-Pin Interface)
R
CR1
+
CR1
To User Equipment
Pin I, J: Collector
Pin G: Emitter
2-4.
Automation Connection (For 28-Pin Receptacle If Present)
804746-B / 218716-A
1
4
9
15
21
26
28
25
20
14
8
3
2
7
6
5
13
12
11
10
19
18
17
16
24
23
22
27
Remote 14
Socket
Socket Information
15 Volts DC Output
Contactor
A
Contactor c15 volts DC, referenced to G.
B
Contact closure to A completes 15 volts DC con-
tactor control circuit and enables output.
Remote Output
Control
C
Output to remote control; +10 volts DC output to
remote control.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from re-
mote control.
1
Reconfigurable as input for Output Enable
(Weld Stop) - used to remotely stop the weld
outside the normal welding cycle. Connection to
the D socket must be maintained at all times. If
the connection is broken, output stops, and Auto
Stop is displayed.
Output Signals
F
Current feedback; +1 volt DC per 100 amps
output.
H
Voltage feedback; +1 volt DC per 10 volts
output.
I
1
Valid arc indication closed to socket G with valid
arc. Electrical specifications: open collector tran-
sistor (see Section 5-5 for connection example).
J
1
Arc length control lockout closed to socket G
during Initial and Final Amperage and Slope,
and during the background time of a <=10 Hz
pulse waveform. Electrical specifications: open
collector transistor (see Section 5-5 for connec-
tion example).
2
Touch Sense Detection closed to Socket G, with
Modbus’s Touch Sense enabled and machine
not triggered for weld output.
Common
G
Return for all output signals: F, H, I, J and A.
Chassis
K
Chassis
Serial
Communication Bus
L
2
Modbus Common (RS485 Common)
M
2
Modbus D1 (RS485 B+)
N
2
Modbus D0 (RS485 A-)
Sockets G and K are electrically isolated from each other.
1
Available with optional Automation Expansion memory card.
2
Available with optional Modbus Expansion memory card. Modbus serial communication provides access to all front panel parameters and
machine functionality. See Owner’s Manual 265415 for a list of Modbus registers. Modbus expansion also includes functionality of Automa-
tion, Hot Wire, and Hot Start Adjust expansions.
�
If a remote hand control like the RHC-14 is connected to the Remote 14 receptacle, some current value above min. must be set on the
remote control before the Panel or Remote contactor is turned on. Failure to do so will cause current to be controlled by the panel con-
trol, and the remote hand control will not function.
5-5.
Simple Automation Application
Pin I, J: Collector
Pin G: Emitter
To User Equipment
Coil CR1 resistance plus R should be chos-
en to limit current to 75 mA.
User supplied power up to 27 volts DC peak.
Summary of Contents for Dynasty 400
Page 78: ...OM 275857 Page 68 275852 H Figure 12 2 Dynasty 400 Circuit Diagram Page 2 of 2...
Page 80: ...OM 275857 Page 70 Figure 12 4 Maxstar 400 Circuit Diagram Page 2 of 2...
Page 81: ...OM 275857 Page 71 275854 G Figure 12 5 Dynasty 800 Circuit Diagram Page 1 of 2...
Page 82: ...OM 275857 Page 72 275854 G Figure 12 6 Dynasty 800 Circuit Diagram Page 2 of 2...
Page 83: ...OM 275857 Page 73 Figure 12 7 Maxstar 800 Circuit Diagram Page 1 of 2...