OM-275857 Page 81
15-3. General (GEN) Tungsten To Change Programmable TIG Starting Parameters
OM-275857 Page 19
1
2
Current (A)
Start Time
Start Slope Time
Preset Amperage Minimum
S
ta
rt
A
m
p
e
ra
g
e
3
GEN
TUNG
Available Parameter Settings
OM-275857 Page 19
1
2
Current (A)
Start Time
Start Slope Time
Preset Amperage Minimum
S
ta
rt
A
m
p
e
ra
g
e
3
GEN
TUNG
1
Amperage Adjustment Control
2
Parameter Display
3
Amperage Button
Once inside the machine set up menu, tung-
sten parameter values can be manually
changed by pressing the Amperage switch
pad to step through each adjustable parame-
ter. Rotate encoder to change the value.
Parameter
Default AC
Default DC
Range
Start Output Polarity (POL)
EP (Electrode Positive)
EN (Electrode Negative)
EP/EN
Start Amperage (STRT)
30 A
60 A
5–200 A
Start Time (TIME)
140 ms
30 ms
0–250 ms
Start Slope (SSLP)
10 ms
50 ms
0–250 ms
Preset Minimum Amperage
(PMIN)
10 A
5 A
1–25 A (DC)
2–25 A (AC)