OM-275857 Page 54
�
Complete Parts List is available at www.MillerWelds.com
8-4.
Programmable TIG Start Parameters
1
Amperage Button
2
Encoder Control
3
Ammeter
A. Off/On (Start Amperage And Time)
4-4.
Programmable TIG Start Parameters
2
3
1
A. OFF/ON (Start Amperage And Time)
Current (A)
Start Time
S
ta
rt
A
m
p
e
ra
g
e
Off is the default setting. Use Encoder con-
trol to select On. When On is selected, the
Amperage button LED turns on.
Dynasty models have a separate set of pa-
rameters for AC and DC.
The AC and DC parameters are selected re-
motely
through
pin
28
of
the
28-pin
automation receptacle where EP (electrode
positive = AC, and EN (electrode negative)
= DC
Preset Advanced Automation TIG Start
Parameters
Default values for Advanced Automation
TIG Start Amperage and Start Time are as
follows: AC Start Amperage = 50A, AC Start
Time = 30ms. DC Start Amperage = 30A
and DC Start Time = 30ms.
If it is necessary or desired to change the
Advanced Automation TIG Start Amperage
and Start Time values from the default val-
ues, press the amperage button to step
through each adjustable parameter (see
Sections B. and C.).
B. Programmable TIG Start Amperage
A complete Parts List is available at www.MillerWelds.com
Start
Amperage
B. Programmable TIG Start Amperage
Current (A)
C. Programmable Start Time
Current (A)
Start
Time
To adjust TIG Start Amperage proceed as
follows:
Press Amperage button until the current start
amperage is displayed. The current Start
Amperage is displayed on the ammeter, and
can be adjusted by rotating the amperage
adjustment control.
To change Start Time, proceed to Section C.
C. Programmable Start Time
A complete Parts List is available at www.MillerWelds.com
Start
Amperage
B. Programmable TIG Start Amperage
Current (A)
C. Programmable Start Time
Current (A)
Start
Time
To adjust Programmable Start Time proceed
as follows:
Press Amperage button until the current start
time is displayed. The current Start Time is
displayed in milliseconds on the amps meter,
and can be adjusted by rotating the amper-
age adjustment control.
Summary of Contents for Dynasty 400
Page 78: ...OM 275857 Page 68 275852 H Figure 12 2 Dynasty 400 Circuit Diagram Page 2 of 2...
Page 80: ...OM 275857 Page 70 Figure 12 4 Maxstar 400 Circuit Diagram Page 2 of 2...
Page 81: ...OM 275857 Page 71 275854 G Figure 12 5 Dynasty 800 Circuit Diagram Page 1 of 2...
Page 82: ...OM 275857 Page 72 275854 G Figure 12 6 Dynasty 800 Circuit Diagram Page 2 of 2...
Page 83: ...OM 275857 Page 73 Figure 12 7 Maxstar 800 Circuit Diagram Page 1 of 2...