OM-2240 Page 13
SECTION 4
−
INSTALLATION
4-1. Specifications
Input Power
Rated Output
Welding
Amperage
Max.
Open-Circuit
Amperes Input At Rated Output, 50/60Hz
KVA
KW
Input Power
Rated Output
Amperage
Range **
Open-Circuit
Voltage
115
230
400
460
KVA
KW
Three-Phase
Stick Process
130 A @ 25.2 VDC,
60% Duty Cycle
1
−
200
80
∇
5-10
♦
-
−
12.3
0.16*
7.6
0.24*
6.0
0.25*
4.8
0.06*
4.6
0.03*
Three-Phase
TIG Process
150 A @ 16 VDC,
60% Duty Cycle
1
−
200
80
5-10
♦
-
−
9.4
0.16*
6.0
0.24*
4.7
0.25*
3.8
0.06*
3.6
0.03*
Three-Phase
Stick Process
200 A @ 28 VDC,
20% Duty Cycle
1
−
200
80
∇
5-10
♦
20.8
0.16*
13.0
0.24*
10.2
0.25*
8.1
0.06*
7.8
0.03*
Three-Phase
TIG Process
200 A @ 18 VDC,
20% Duty Cycle
1
−
200
80
5-10
♦
13.7
0.16*
8.7
0.24*
6.9
0.25*
5.5
0.06*
5.2
0.03*
Single-Phase
Stick Process
130 A @ 25.2 VDC,
60% Duty Cycle
1
−
200
80
∇
5-10
♦
-
−
20.0
0.23*
-
−
10.0
.25*
4.7
0.05*
4.7
0.02*
Single-Phase
TIG Process
150 A @ 16 VDC,
60% Duty Cycle
1
−
200
80
5-10
♦
-
−
15.8
0.23*
-
−
7.9
.25*
3.6
0.05*
3.6
0.02*
Single-Phase
Stick Process
100 A @ 24 VDC,
60% Duty Cycle
1
−
200
80
∇
5-10
♦
31.3
0.42*
-
−
-
−
-
−
3.6
0.05*
3.6
0.03*
Single-Phase
TIG Process
140 A @ 15.6 VDC,
40% Duty Cycle
1
−
200
80
5-10
♦
31.0
0.42*
-
−
-
−
-
−
3.6
0.05*
3.5
0.03*
Single-Phase
Stick Process
90 A @ 23.6 VDC,
100% Duty Cycle
1
−
200
80
∇
5-10
♦
27.6
0.42*
-
−
-
−
-
−
3.2
0.05*
3.2
0.03*
Single-Phase
TIG Process
100 A @ 14 VDC,
100% Duty Cycle
1
−
200
80
5-10
♦
20.7
0.42*
-
−
-
−
-
−
2.3
0.05*
2.3
0.03*
*While idling
** Welding range for AC output is 5
−
200 amperes
♦
Low open-circuit voltage while in TIG Lift Arc
t
, or while in Stick with low open-circuit voltage selected.
∇
Normal open-circuit voltage (80 volts) is present while in Stick with normal open-circuit voltage selected.
NOTE: Duty cycle limitations on units with 115 volt input power are due to the input power cord supplied with the unit.
NOTE: This unit is equipped with Auto-Line
t
. The Auto-Line circuitry automatically connects to 120
−
460 VAC, single- or three-phase power without
removing the cover to relink the power source.