OM-2240 Page 56
7-4. Troubleshooting
Trouble
Remedy
No weld output; unit completely
inoperative.
Place line disconnect switch in On position (see Section 4-12 or 4-13).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 4-12 or 4-13).
Check for proper input power connections (see Section 4-12 or 4-13).
No weld output; meter display On.
If using remote control, be sure correct process is enabled to provide output control at Remote 14
receptacle (see Section 4-7 as applicable).
Input voltage outside acceptable range of variation (see Section 4-11).
Check, repair, or replace remote control.
Unit overheated. Allow unit to cool with fan On (see Section 4-4).
Erratic or improper weld output.
Use proper size and type of weld cable (see Section 4-6).
Clean and tighten all weld connections (see Section 4-6).
Fan not operating.
Check for and remove anything blocking fan movement.
Have Factory Authorized Service Agent check fan motor.
Wandering arc
Use proper size tungsten (see Section 10).
Use properly prepared tungsten (see Section 10).
Reduce gas flow rate (see Section 4-8).
Tungsten electrode oxidizing and not re-
maining bright after conclusion of weld
Shield weld zone from drafts.
maining bright after conclusion of weld.
Increase postflow time (see Section 5-1).
Check and tighten all gas fittings (see Section 4-8).
Water in torch. Refer to torch manual.