OM-2240 Page 31
5-14. Memory (Program Storage Locations 1-4) (DX And LX Models If Available)
1
Memory (Program Storage
1-4) Switch Pad
2
Polarity Switch Pad
3
Process Switch Pad
To create, change, or recall a
welding parameters program,
proceed as follows:
First, press Memory switch pad until
the desired program storage loca-
tion (1-4) LED is illuminated
Second, press Polarity switch pad
until the desired polarity, AC or DC,
LED is illuminated
Third, press Process switch pad un-
til desired process, TIG HF Impulse,
TIG Lift Arc, or Stick, LED is illumi-
nated.
The program at the chosen location,
for the desired polarity and process,
is now the active program.
Fourth, change or set all desired pa-
rameters (see Section 5-1 for pa-
rameters).
1
2
3
1st
2nd
3rd
Memory Locations
1
−
4
AC
DC
TIG (HF or Lift)
TIG (HF or Lift)
Stick
Stick
Each memory location (1 thru 4) can store parameters for both
polarities, and each polarity can store parameters for both pro-
cess (TIG or Stick) for a total of 16 programs.
And
And
And
.
Some features shown are
not available on all models.