Complete Parts List available at www.MillerWelds.com
OM-282374 Page 43
6-6. Arc Control Settings
Arc Control is not active when the Process/Contactor switch is in the following positions:
Electrode Hot
−
CAC-A (Air Carbon Arc Gouging)
Remote ON/OFF GTAW (Remote TIG)
Miller recommends Hobart filler metals.
Process/Contactor Switch
Arc Control
Voltage sensing feeder
SOFT
(
−
25 to
−
1)
Starting point for stainless steel wire (high inductance)
SOFT
-12
(0)
Starting point for mild steel wire
STIFF
(1 to 25)
Starting point for aluminum wire (low inductance)
STIF
12
SOFT
(
−
25 to
−
1)
Flat or horizontal welds with XX18 electrode with short weld cables
(0)
Starting point for XX18, XX13, XX14, XX24, and XX22 electrodes
STIFF
(1 to 25)
Minimizes stickiness with XX18, XX14, XX22, XX24, and XX13
electrodes.
STOP
(
−
5 to
−
1)
Auto-Crater off (see Section 6-5). More sensitive Auto-Stop
(0)
Starting point.
STOP
(1 to 5)
Less sensitive Auto-Stop
Lift-Arc start. No Auto Crater allows full control on pipe welds with
short or long arc length. Auto Stop feature allows arc to be broken
without loss of shielding gas.
STOP
(
−
5 to
−
1)
Auto Crater on (see Section 6-5). More sensitive Auto-Crater
initiation
(0)
Starting point
STOP
(1 to 5)
Less sensitive Auto-Crater initiation
SOFT
(
−
25 to
−
1)
(0)
Starting point
STIFF
(1 to 25)