6-5. Service Menu
1
Adjust Control/Select Button
Press and hold control for 5 seconds,
then release to access the Service
Menu. Rotate the knob to scroll
through the menu items. Press and
release the control to access the op-
tions and information within each
menu item.
Rotate the control counterclockwise
to decrease the value or select NO/
OFF. Rotate the control clockwise to
increase the value or select YES/
ON.
Press and release control to save se-
lection. After 5 seconds of inactivity,
the menu will time out and the selec-
tion will not be saved.
1
277078
Menu Item
Selectable Item
Option(s)
Description
HOT STRT
(Only accessible in SMAW
processes)
LIMT OFF
Disables Hot Start option.
LIMT 1.25
Sets Hot Start current limit, selectable between 1.25 and 2.0 (0.25 increments) in
SMAW XX10 and SMAW Remote.
LIMT 1.50
Sets Hot Start current limit, selectable between 1.5 and 3.0 (0.5 increments) in
SMAW XX18.
DIG RNGE
50 - 150
Sets current limit above preset amperage between 50 and 150 amps.
AUTO CRTR
(Only accessible in GTAW
processes)
ATCR ON
Enables Auto Crater option.
ATCR OFF
Disables Auto Crater option.
VRD*
VRD ON
Enables VRD (Voltage Reducing Device) option, lowering open-circuit voltage.
VRD OFF
Disables VRD (Voltage Reducing Device) option.
SOFT WARE
−
−
Displays the current revision of firmware installed.
FACT RSET*
RSET YES
Resets all settings to factory defaults.
RSET NO
All settings remain at previous settings.
*On Side A, user must first select whether to apply settings to Side A only or to both sides.