OM-262 752 Page 29
5-9.
Making Dual Operator CV Weld Connections w/ Separate Work Cables
Welder A (Left) Side
Welder B (Right) Side
258 836
!
Stop engine.
NOTICE − Do not exceed machine duty
cycle.
Use Dual Operator mode for CC and
CV welding (see Section 6-2).
See Section 5-14 for proper cable size.
1
Wire Feeder Cables
2
Work Cables
For MIG and FCAW welding Direct Current
Electrode Positive (DCEP), connect work
cables to Negative (−) terminals and wire
feeder cables to Positive (+) terminals.
For MIG and FCAW Direct Current Elec-
trode Negative (DCEN), connect work
cables to Positive (+) terminals and wire
feeder cables to Negative (−) terminals.
Be sure Process Selector switches are
set correctly. See Section 6-4.
Tools Needed:
3/4 in.
1
1
2
2
Direct Current Electrode Positive
(DCEP) connections are shown.