Complete Parts List available at www.MillerWelds.com
OM-262 752 Page 42
6-9.
Remote Voltage/Amperage Control
1
Remote 14 Receptacle
Connect optional remote control to receptacle
(see Section 5-15).
When a remote control is connected to the
Remote receptacle, the Auto Sense Re-
mote feature automatically switches volt-
age/amperage control to the remote con-
trol. When a device is connected to the Re-
mote receptacle, remote voltage/amper-
age control is always available regardless
of the position of the Process/Contactor
switch.
2
Voltmeter
3
Ammeter
0774 / Ref.246 345-B / Ref. 907 561−06
Turn Remote Control On. Ad-
just Optional Remote
Control to 100%
Set V/A Control
To Desired Maximum
Weld Output Using Weld
Meters
Set TIG or STICK Process
In Example:
Min = 20 A DC
Max = 205 A DC
Max (205 A DC)
Min (20 A DC)
Connect Remote
Control To Remote
Receptacle RC14
Adjust Optional Remote
Control to desired
weld output
Ammeter Shows Preset
Output When Not Welding,
Actual Amperage While
Welding
Set WIRE Process
Connect Remote
Control To Remote
Receptacle RC14
Adjust Optional Remote
Control to desired
weld output
1
2
3
CC Welding
CV Welding
85
205
Voltmeter Shows Open-Circuit
Voltage When Not Welding, Arc
Voltage While Welding
Electrode Hot: Voltmeter tog-
gles between preset and ac-
tual output when not welding,
actual voltage while welding.
Remote On/Off Required:
Voltage shown is preset.
28
0
Ammeter Shows Zero