Complete Parts List available at www.MillerWelds.com
OM-262 752 Page 41
6-8.
Lift-Arc
t
TIG With Auto-Stop
t
WM Marketing
Arc Start With Lift-Arc
Arc End With Auto-Stop
1
2
2
1
3
Arc Start With Lift-Arc TIG
Lift-Arc is used for the DCEN
GTAW process when HF Start
method is not permitted.
Select Lift-Arc TIG at Process/
Contactor switch.
Turn gas on.
1
Touch or scratch.
2
Lift at any angle.
Touch tungsten electrode to
workpiece at weld start point.
Slowly lift electrode. Arc is started
when electrode is lifted.
Maintain shielding gas coverage
and eliminate tungsten and work-
piece contamination by using
Auto-Stop to end the arc.
Arc End With Auto-Stop:
1
While welding.
2
Lift torch to start Auto-Stop.
Arc stops.
3
Move torch back down to
maintain gas coverage and
prevent contamination.
Notes